Click on the sensor to the plate and begin the calibration process.
There are two methods of calibrating the bucket sensor: Manual and Automatic. The manual process is
much quicker, although you will need some additional items. The automatic process is similar in concept
to the Excavator setup, whereby you will move the bucket through a series of incremental changes while
keeping the bucket blade on a fixed point.
If the bucket sensor is located on the dog-bone an automatic calibration is your only option.
For a manual calibration you will need a magnetic plumb-bob and a tape measure. For an automatic
calibration a tape measure and something to use as the set-point is required. A traffic/road cone is an ideal
item.
Begin by selecting the location in which
the sensor has been installed.
Press “Next” to continue
Manual Bucket Calibration
-Quicklink
As previously mentioned the manual
bucket calibration is a much quicker
process than the automatic calibration.
It is imperative that you are ABSOLUTLEY
accurate with your measurements and
vertical angle position of the bucket when
proceeding with the following steps.