KS-6215 / KS-6215I / KS-6217 series Technical Manual 5 - 6
power off, he/she should consult his/her dealer for application of an external 12 V
battery.
When the UPS battery is installed in the KS system with power off, the standby
current will consume the battery much faster than self-discharge. An over-discharged
battery will not only mean premature death of the battery itself, it also may cause
danger when later being recharged. It is therefore absolutely important that the end
user shall
disconnect the UPS battery from the system when the system is to be
powered off for more than 72 hours and replace a new battery whenever the
monitoring software indicates the battery is out of service
.
UPS BATTERY HEALTH CHECK
The UPS battery health check watchdog function is introduced in the Posiflex
Power Switch Manager utility version 1.03 onwards. This function helps checking the
UPS battery condition and automatically popping up warning message window to
remind the user of a possibly failed battery so that the user won’t have to bother
checking in the Posiflex Power Switch Manager personally every time.
Listed below are command code strings to COM1 port under protocol: 9600
bps, parity none, 8 data bits, 1 stop bit for reference if the software programmer wants
to issue separate commands directly:
Ÿ
To enable UPS function: <06> <16> <19> <1F> <05> or <1B> <00>
<00> <00> <00> <18> <00> <18>
Ÿ
To disable UPS function: <06> <16> <19> <1F> <04> or <1B> <00>
<00> <00> <00> <18> <18> <00>
Ÿ
“Check Battery-Detect Capability” command string is <1B> <00> <00>
<00> <00> <18> <00> <00> in hexadecimal format. And the DCD of
COM1 will be set for a period of time if the battery-detect capability of the
system is operating.
Ÿ
“Check Battery Condition” command string is <1B> <00> <00> <00>
<00> <18> <18> <18> in hexadecimal format. And the DCD of COM1
will be set for a period of time if the battery responds correctly to the
battery detect.
The period of time in last 2 responses starts after several machine cycles since
receival of the query command and stops about 15 seconds later or whenever another