SERVICE MANUAL
CYKLON 5000
Page 21
Service manual C
yklon - V
. 1.0 - 10-03-22 Appr
ov
ed by: JN
ASSEMBLY - 2nd STAGE 1133, 3224, 3354, 3354 M, 3536
Install the exhalation diaphragm (21) on
the diaphragm housing. Make sure that the
diaphragm is laying flat on the diaphragm
housing.
Install exhalation diaphragm cover (20) and
locking ring (19).
Install the diaphragm housing on the mouthpiece
tube. Be sure to slip the operating device into the
diaphragm guide sleeve.
Checking the second stage for leaks: Place the
mouth piece against your lips the low pressure
hose correction with your thumb and inhale lightly.
This will create a partial vacuum inside the
second stage. If the pressure does not equalize in
5 seconds the second stage leaks.
See chapter Fault-tracing scheme.
Install the o-ring (2) on the LP hose and lubricate
Screw on the LP-hose.Do not tighten the
connecting ring until after the function test.