background image

13. 

Slide the guide with the handles onto the slat pins upwards from 

   

the bottom of the blind. Insert the handle pins (1.) carefully into the 

   

upper part of the guides. Check if the elements are installed 

   

correctly. Do not push the blind guides onto the pins which may 

   

damage the guides

.

14. 

Measure the position of the guide axis carefully, then 

   

screw the guides to the ground

.

15. 

Install the guide end caps

.

16. After checking the correctness of the external blind operation, 
   set the roller mechanism in a vertical axis with the winding tape, 
   and then tighten the counter screws (1).

17. 

Insert safety plate extensions into previously installed 

   

wall handles

 

and screw them

.

18. 

Place the extension silencing element onto the lower parts 

   

of the extensions

.

12. 

Slide the guide handle into the rear wall of the guide 

   

and block the handle by tightening the grub screw. 

   

The maximum distance between the handles should 

   

not exceed 800mm

.

5

max. 800mm

1.

11. 

Join the guide with the supplied crank by means of connecting 

   

elements (provided by the PORTOS company) as in Figure 1. 

   

Install the crank clip to the wall with screws (dowels)

.

1.

ZF3000 

EXTERNAL BLIND INSTALLATION

1

Содержание ZF3000 C80

Страница 1: ...R INSTRUCTIONS FOR INSTALLATION AND SERVICE OF ZF3000 EXTERNAL BLIND ...

Страница 2: ......

Страница 3: ...XTERNAL BLIND INSTALLATION 1 Tools needed to install the external blind The PORTOS company does not provide screws dowels cables for placing the electrical installation 2 In the case of dimensioning the dimension smallest from the measurements taken is the right dimension Dimensioning ZF3000 external blind aluminium guides installation in the window Dimensioning ZF3000 external blind aluminium gui...

Страница 4: ...nside of the room through the previously prepared hole in the wall or window depending on the installation method Screw the manual drive guide 2 to the wall 4 3 The installation place of wall handles should not interfere with the proper functioning of the blind lifting and lowering mechanisms crank motor The maximum distance between the handles should not exceed 800mm 5 Install the top guide handl...

Страница 5: ...the roller mechanism in a vertical axis with the winding tape and then tighten the counter screws 1 17 Insert safety plate extensions into previously installed wall handles and screw them 18 Place the extension silencing element onto the lower parts of the extensions 12 Slide the guide handle into the rear wall of the guide and block the handle by tightening the grub screw The maximum distance bet...

Страница 6: ...overlap on the facade Wbo height of the safety plate Wz Wo Wp or Wbo INSTALLATION ON THE FACADE Sz So slat overlap on the facade FLUSH MOUNTED Sz window width 2 In the case of dimensioning the dimension smallest from the measurements taken is the right dimension 3 The installation place of wall handles should not interfere with the proper functioning of the blind lifting and lowering mechanisms cr...

Страница 7: ... the top rail handle 11 In the case of external blinds with manual drive after installing the blind package put the crank pin 1 in the manual drive gear by placing it from the inside of the room through the previously prepared hole in the wall or window depending on the installation method Screw the manual drive guide 2 to the wall 10 Join the guide with the supplied crank by means of connecting e...

Страница 8: ...ght 17 Run the cord through the adjustment screw 1 and lock it using an Allen key Mount the adjustment screw in the lower handle 2 Tighten the nut on the adjustment screw with the key thus tightening the cord Leave some clearance for the proper operation of the mechanism 18 After checking the correctness of the external blind operation set the roller mechanism in a vertical axis with the winding t...

Страница 9: ...3000 external blind aluminium guides installation in the window Dimensioning ZF3000 external blind aluminium guides installation on the facade flush mounted Sz So Wz Wo EXPLANATIONS TO DIMENSIONING Sz blind width So hole width Wz blind height Wo hole height Sz So Wz Wo So Wo Wz Wp P P EXPLANATIONS TO DIMENSIONING Sz blind width slat width So hole width Wz blind height Wo hole height Wp package heig...

Страница 10: ...lling marked 6 Make a cut for the wall handle hole in the marked places in the safety plate Then cut or break off a piece of metal sheet in the places of mounting handles as shown above 7 Attach the insulation component on the back side of the safety plate E with double sided tape or appropriate adhesive 8 Fasten the guides with the appropriate screws to the window frame 9 Place the safety plate E...

Страница 11: ...tion about the installation side is on the window side 14 Screw the bottom end caps to the guide with the 3x16 mm screws included in the set 15 Check the correct installation of the blind adjust if necessary 16 Depending on the height of the safety plate set the safety plate extensions 1 to the correct height and fasten them to the handles using the screws from the inside of the box as shown above...

Страница 12: ...opposite direction When the blind is fully open or closed the motor will be automatically stopped by the limit switch Use the scroll wheel on the remote for precise setting the position of the external blind slats In case of noticing that the blind curtain has stopped and the motor is still running stop the motor immediately by pressing the MY button on the remote in the case of a switch with non ...

Страница 13: ...product The blind should be cleaned with a soft cloth using generally available cleaning agents The use of pressure washers strong cleaning agents and solvents is forbidden When cleaning the product it is absolutely not advisable to use sharp tools and cleaning agents that cause scratches In the case of cleaning the product it is unconditionally necessary to prevent the possibility of water gettin...

Страница 14: ...IONS IS IMPORTANT FOR THE SAFETY OF PERSONS KEEP THESE INSTRUCTIONS 11 PORTOS TR7 spółka z ograniczoną odpowiedzialnością s k PN EN 13659 All of the certificates of the useful properties are available on the website www portos company ...

Отзывы: