background image

Installation and care

instructions

Insect screen pleated blind

For qualified technicians only

To be handed over to the opera-

tor.

Please keep for future use.

Valid from 19 April 2017

2021216 [Rev. 2 - en]/2017-04-19

Page 1 | 8

Installation and care

instructions

Insect screen pleated blind

For qualified technicians only

To be handed over to the opera-

tor.

Please keep for future use.

Valid from 19 April 2017

2021216 [Rev. 2 - en]/2017-04-19

Page 1 | 8

1

Safety and product information

Warnings are marked in the instructions with this
symbol.

Read through the product instructions before

use.
Observe all safety and setting instructions.

The basic safety instructions

can be viewed under

(

www.warema.de/Sicherheitshinweise

).

Target group

These instructions are intended for use by persons who
install, operate, care for and/or maintain the product.

Persons installing the product must be familiar with the
following areas: occupational safety, accident prevention
regulations, working with ladders, usage of fixing materials,
and the commissioning and operation of the product.

If the fitter lacks any one of these qualifications, the work
must be carried out by a specialist fitting company.

Contents

These instructions are an integral part of the following
product:
Insect screen pleated blind P1.Q.xx (one-wing) and P2.Q.xx
(two-wing) 

Intended use

The following details apply to the following product: Insect
screen pleated blind P1.Q.xx (one-wing) and P2.Q.xx (two-
wing) 

The product is a horizontally movable insect screen pleated
blind for outdoor use.

The product does not offer fall protection at windows. The
necessary safety measures must be provided as legally
stipulated.

The intended use also includes observing these instructions
and adhering to the service requirements they describe.

Parts description

Designation

Description

P1.Q.20

Insect screen pleated blind without

mounting frame

P1.Q.21

Insect screen pleated blind with 4-

sided mounting frame

P1.Q.22

Insect screen pleated blind with 3-

sided mounting frame (open at the

bottom)

P1.Q.23

Insect screen pleated blind with lat-

eral mounting frame profiles

P2.Q.xx

Insect screen pleated blind, two-wing

(for model, see P1.Q.xx)

Tab. 1:

Overview of models

1

2

3

4

5

1

Fabric package with
handle rail and end
profile

4

End profile, opposite
side

2

Ceiling profile

5

Base profile

3

Guide rail, top

Fig. 1:

Parts overview of insect screen pleated blind

P1.Q.20

Содержание P2.Q Series

Страница 1: ...se qualifications the work must be carried out by a specialist fitting company Contents These instructions are an integral part of the following product Insect screen pleated blind P1 Q xx one wing and P2 Q xx two wing Intended use The following details apply to the following product Insect screen pleated blind P1 Q xx one wing and P2 Q xx two wing The product is a horizontally movable insect scre...

Страница 2: ... for se curing the ceiling profile Mounting profile bottom in P1 2 Q 21 39 100 Mounting profile right In P1 2 Q 22 no mitre cut at the bot tom In P1 2 Q 23 no mitre cut and fixing holes in the same surface 100 39 Mounting profile left In P1 2 Q 22 no mitre cut at the bot tom In P1 2 Q 23 no mitre cut and fixing holes in the same surface Corner joint connectors P1 2 Q 21 4 pieces P1 2 Q 22 2 pieces...

Страница 3: ...ge of opposite side Top edge of ceil ing profile to bottom edge of base profile P1 2 Q 21 Mounting frame di mensions Mounting frame di mensions P1 2 Q 22 Mounting frame di mensions Top edge of mount ing frame to bottom edge of base profile P1 2 Q 23 Back edge of lateral mounting profile Top edge of ceil ing profile to bottom edge of base profile Tab 8 Order width and order height depending on mode...

Страница 4: ...he mounting frame Attach the ceiling pro file P1 2 Q 23 Hold the ceiling profile between the mounting profiles on the mounting substructure Transfer the drill hole position Drill the fixing holes Attach the ceiling pro file Attaching the base profile P1 2 Q 20 23 Slide the fixing brack ets into the base profile at the bottom on both sides INFO The fixing brackets at the bottom can be shifted in th...

Страница 5: ...d Inserting the pleated blind in the ceiling and base profiles 2 1 3 Insert the package in the guide rail Lower the package into the base profile Remove the safety straps on the package Attaching the end profiles INFO First attach the end profile of the package side 2 1 Swing in the end profile at the top Press on the end profile to hook it into the brack et 2 1 Press the end profile against the m...

Страница 6: ...and a long service life CAUTION Risk of injury from falling from climbing aid Climbing aids e g ladders scaffolding etc may tip over if improperly erected Position climbing aids on level and firm ground Do not rest climbing aids against the product CAUTION Risk of injury from falling There is a risk of falling during maintenance work Take suitable safe measures to prevent or stop a fall 3 1 Cleani...

Страница 7: ...by the GRM Gütegemeinschaft Reinigung von Fassaden e V certification no 142 242 342 442 542 To order contact your WAREMA dealer For further advise and in technical matters regarding cleaning please contact the Verband Deutscher Sonnenschutzreiniger e V www vds sonnenschutz de Preparing cleaning When cleaning the product protect adjacent areas against soiling Aids required for cleaning Soft brush d...

Страница 8: ...ed by a qualified specialist according to the WAREMA maintenance checklist The maintenance checklist is available from your specialist dealer or can be requested from WAREMA 3 3 Spare parts repairs INFO To ensure that your product will operate properly on a continuous basis and to avoid changing its approved status use original spare parts only Contact your WAREMA specialist dealer if necessary 3 ...

Отзывы: