background image

5-ENG

RISK FROM MOVING PARTS

                 RISK OF BURNS

                RISK OF FALLING

IMPORTANT SAFETY INSTRUCTIONS (cont’d)

WHAT CAN HAPPEN

HOW TO PREVENT IT

WHAT CAN HAPPEN

HOW TO PREVENT IT

WHAT CAN HAPPEN

HOW TO PREVENT IT

MOVING PARTS

 SUCH AS THE PULLEY,

FLYWHEEL, AND BELT 

 CAN CAUSE SERIOUS

INJURY

  IF THEY COME INTO CONTACT WITH YOU

OR YOUR CLOTHING.

ATTEMPTING TO OPERATE

 COMPRESSOR 

WITH

DAMAGED OR MISSING PARTS  OR ATTEMPTING
TO REPAIR COMPRESSOR WITH PROTECTIVE
SHROUDS REMOVED CAN EXPOSE YOU TO
MOVING PARTS 

AND CAN 

RESULT IN SERIOUS

INJURY.

TOUCHING EXPOSED METAL

 SUCH AS THE

COMPRESSOR HEAD OR OUTLET TUBES,  

CAN

RESULT IN SERIOUS BURNS.

NEVER OPERATE

 THE 

COMPRESSOR WITH

GUARDS

 OR COVERS WHICH ARE DAMAGED OR

REMOVED.

ANY 

REPAIRS

 REQUIRED ON THIS 

PRODUCT

SHOULD BE PERFORMED BY AUTHORIZED
SERVICE CENTER PERSONNEL.

NEVER TOUCH ANY EXPOSED METAL PARTS ON
COMPRESSOR

 DURING OR IMMEDIATELY AFTER

OPERATION.

 COMPRESSOR WILL REMAIN HOT

FOR SEVERAL MINUTES AFTER OPERATION.

DO NOT REACH AROUND PROTECTIVE SHROUDS
OR ATTEMPT MAINTENANCE UNTIL UNIT HAS
BEEN ALLOWED TO COOL.

A PORTABLE 

COMPRESSOR CAN FALL

 FROM A

TABLE, WORKBENCH OR ROOF 

CAUSING

DAMAGE TO THE COMPRESSOR AND COULD
RESULT IN SERIOUS INJURY OR DEATH TO THE
OPERATOR OR BYSTANDERS.

ALWAYS 

OPERATE COMPRESSOR IN A STABLE

SECURE POSITION

 TO PREVENT ACCIDENTAL

MOVEMENT OF THE UNIT.  

NEVER OPERATE

COMPRESSOR ON A ROOF OR OTHER ELEVATED
POSITION.  USE ADDITIONAL AIR HOSE TO
REACH HIGH LOCATIONS.

WHAT CAN HAPPEN

HOW TO PREVENT IT

RISK OF PROPERTY DAMAGE WHEN

TRANSPORTING COMPRESSOR

(Fire, Inhalation, Damage

to Vehicle Surfaces)

OIL CAN LEAK OR SPILL

 AND COULD RESULT

IN FIRE OR BREATHING HAZARD, SERIOUS
INJURY OR DEATH CAN RESULT.  OIL LEAKS WILL
DAMAGE CARPET, PAINT OR OTHER SURFACES
IN VEHICLES OR TRAILERS.

ALWAYS PLACE COMPRESSOR ON A PROTECTIVE
M AT WHEN TRANSPORTING TO PROTECT
AGAINST DAMAGE TO VEHICLE FROM LEAKS.
REMOVE COMPRESSOR FROM VEHICLE
IMMEDIATELY UPON ARRIVAL AT YOUR
DESTINATION.

ESW-99 — 9/26/99

Содержание CPF23400P

Страница 1: ...n the frame Record these numbers in the spaces below and retain for future reference Model No Type Serial No ESPA OL P GINA 19 FRAN AISE PAGE 37 IMPORTANT Please make certain that the person who is to...

Страница 2: ...e nearest Autho rized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following information Model...

Страница 3: ...IRE AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY HAZARD WHAT CAN HAPPEN HOW TO PREVE...

Страница 4: ...AIR FROM THE COMPRESSOR EITHER DIRECTLY OR FROM A BREATHING DEVICE CONNECTED TO THE COMPRESSOR WORK IN AN AREA WITH GOOD CROSS VENTILATION READ AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON THE LABEL...

Страница 5: ...AFTER OPERATION COMPRESSOR WILL REMAIN HOT FOR SEVERAL MINUTES AFTER OPERATION DO NOT REACH AROUND PROTECTIVE SHROUDS OR ATTEMPT MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL A PORTABLE COMPRESSOR C...

Страница 6: ...es Standards for Safety Porter Cable air compressors should be operated on not more than a 50 duty cycle This means an air compressor that pumps air more than 50 of one hour is considered misuse becau...

Страница 7: ...compressed air from the compressor head and the outlet tube when the air compressor reaches cut out pressure or is shut off The pressure release valve allows the motor to restart freely When the motor...

Страница 8: ...must be used use only a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the extension cord make sure the extension cord is in good conditio...

Страница 9: ...the same configuration as the plug See Fig 3 DO NOT USE AN ADAPTER Inspect the plug and cord before each use Do not use if there are signs of damage Improper grounding can result in electrical shock D...

Страница 10: ...rain water from air tank by opening drain cock valve on bottom of tank WATER WILL CONDENSE IN THE AIR TANK IF NOT DRAINED WATER WILL CORRODE AND WEAKEN THE AIR TANK CAUSING A RISK OF AIR TANK RUPTURE...

Страница 11: ...ll air tank pressure and allow unit to cool before doing any maintenance or repair Never operate the unit with the belt guard removed To ensure efficient operation and longer life of the air compresso...

Страница 12: ...otor Wiring Diagram The motor connection diagram is located on the side of motor STORAGE Before you store the air compressor make sure you do the following 1 Review the Maintenance section on the prec...

Страница 13: ...NOT OVER TIGHTEN Air leaks at or inside check valve Malfunctioning or dirty check valve A malfunctioning check valve results in a constant air leak at the pressure release valve when pressure is in th...

Страница 14: ...cessary Have checked by an Authorized Warranty Service Center Do not operate the compressor in the paint spray area See flammable vapor warning 1 Check fuse box for blown fuse and replace if necessary...

Страница 15: ...e in hose Check valve restricted Air leaks Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger...

Страница 16: ...tion of components within the air line Do not mix different styles of bodies plugs HOSE 3 8 I D HOSE Ideal for increasing working distance in high CFM applications 1 4 COIL HOSE Self retracting and li...

Страница 17: ...17 ENG NOTES...

Страница 18: ...erials or other contaminants Expendable items that become worn during normal use such as drain valves fuses filters belts air cleaners spark plugs engine oil and pump oil Cosmetic defects that do not...

Отзывы: