RISK OF BURSTING

IT IS NORMAL FOR ELECTRICAL CONTACTS

WITHIN THE MOTOR AND PRESSURE SWITCH 

TO

SPARK.

IF

 ELECTRICAL 

SPARKS

 FROM COMPRESSOR

COME INTO CONTACT WITH FLAMMABLE
VAPORS, THEY MAY IGNITE, CAUSING FIRE OR
EXPLOSION.

RESTRICTING

 ANY OF THE 

COMPRESSOR

VENTILATION OPENINGS WILL CAUSE SERIOUS
OVERHEATING AND COULD CAUSE FIRE.

UNATTENDED OPERATION OF THIS PRODUCT
COULD RESULT IN PERSONAL INJURY OR
PROPERTY DAMAGE.

ALWAYS 

OPERATE THE COMPRESSOR IN A

 WELL

VENTILATED 

AREA FREE OF COMBUSTIBLE

MATERIALS, GASOLINE OR SOLVENT VAPORS.

IF SPRAYING FLAMMABLE MATERIALS, 

LOCATE

COMPRESSOR AT LEAST 20 FEET AWAY FROM
SPRAY AREA.

  AN ADDITIONAL LENGTH OF HOSE

MAY BE REQUIRED.

STORE FLAMMABLE MATERIALS IN A SECURE
LOCATION AWAY FROM COMPRESSOR.

NEVER PLACE OBJECTS AGAINST OR ON TOP
OF COMPRESSOR.  OPERATE COMPRESSOR

 IN

AN OPEN AREA AT LEAST 

12 INCHES AWAY FROM

ANY  WALL OR 

OBSTRUCTION

 THAT WOULD

RESTRICT THE FLOW OF FRESH AIR TO THE
VENTILATION OPENINGS.

OPERATE COMPRESSOR IN A CLEAN, DRY, WELL
VENTILATED AREA.  

DO NOT OPERATE UNIT

INDOORS OR IN ANY CONFINED AREA.

ALWAYS REMAIN IN ATTENDANCE WITH THE
PRODUCT WHEN IT IS OPERATING.

  SAVE THESE INSTRUCTIONS

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY
AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING
INSTRUCTIONS BEFORE USING THIS EQUIPMENT.

RISK OF EXPLOSION OR FIRE

AIR TANK: 

 THE FOLLOWING CONDITIONS COULD

 LEAD TO A WEAKENING OF THE TANK, AND 

RESULT

IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY.

HAZARD

WHAT CAN HAPPEN

HOW TO PREVENT IT

IMPORTANT SAFETY INSTRUCTIONS (cont’d)

DRAIN TANK DAILY OR AFTER EACH USE.

  IF TANK

DEVELOPS A LEAK, REPLACE IT IMMEDIATELY
WITH A NEW TANK OR REPLACE THE ENTIRE
COMPRESSOR.

NEVER

 DRILL INTO, WELD, OR 

MAKE ANY

MODIFICATIONS TO THE TANK

 OR ITS

ATTACHMENTS.

THE TANK IS DESIGNED TO WITHSTAND SPECIFIC
OPERATING PRESSURES. 

 NEVER MAKE

ADJUSTMENTS OR PARTS SUBSTITUTIONS TO
A LTER THE FACTORY SET OPERATING
PRESSURES.

FOR ESSENTIAL CONTROL OF AIR PRESSURE,
YOU MUST 

INSTALL A PRESSURE REGULATOR

AND PRESSURE GAUGE TO THE AIR OUTLET

 OF

YOUR COMPRESSOR. FOLLOW THE EQUIPMENT
MANUFACTURERS RECOMMENDATION AND
NEVER EXCEED THE MAXIMUM ALLOWABLE
PRESSURE RATING OF ATTACHMENTS. 

NEVER

USE COMPRESSOR TO INFLATE SMALL LOW-
PRESSURE OBJECTS SUCH AS CHILDREN’S
TOYS, FOOTBALLS, BASKETBALLS. ETC.

1.

FAILURE TO PROPERLY DRAIN 

CON-

DENSED

 WATER  FROM THE TANK,

CAUSING RUST AND THINNING OF THE
STEEL TANK.

2.

MODIFICATIONS

 OR ATTEMPTED REPAIRS

TO THE TANK.

3.

UNAUTHORIZED 

MODIFICATIONS TO THE

UNLOADER  VALVE, SAFETY VALVE, OR

ANY 

OTHER COMPONENTS WHICH

CONTROL

 TANK 

PRESSURE.

4.

EXCESSIVE VIBRATION CAN WEAKEN THE
AIR TANK AND CAUSE RUPTURE OR
EXPLOSION.

ATTACHMENTS  & ACCESSORIES:

EXCEEDING THE PRESSURE RATING OF AIR
TOOLS,

 SPRAY GUNS, AIR OPERATED

ACCESSORIES, TIRES AND OTHER INFLATABLES

CAN CAUSE THEM TO EXPLODE

 OR FLY APART,

AND COULD RESULT IN SERIOUS INJURY.

WHAT CAN HAPPEN

HOW TO PREVENT IT

Содержание CPF23400P

Страница 1: ...n the frame Record these numbers in the spaces below and retain for future reference Model No Type Serial No ESPA OL P GINA 19 FRAN AISE PAGE 37 IMPORTANT Please make certain that the person who is to...

Страница 2: ...e nearest Autho rized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following information Model...

Страница 3: ...IRE AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY HAZARD WHAT CAN HAPPEN HOW TO PREVE...

Страница 4: ...AIR FROM THE COMPRESSOR EITHER DIRECTLY OR FROM A BREATHING DEVICE CONNECTED TO THE COMPRESSOR WORK IN AN AREA WITH GOOD CROSS VENTILATION READ AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON THE LABEL...

Страница 5: ...AFTER OPERATION COMPRESSOR WILL REMAIN HOT FOR SEVERAL MINUTES AFTER OPERATION DO NOT REACH AROUND PROTECTIVE SHROUDS OR ATTEMPT MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL A PORTABLE COMPRESSOR C...

Страница 6: ...es Standards for Safety Porter Cable air compressors should be operated on not more than a 50 duty cycle This means an air compressor that pumps air more than 50 of one hour is considered misuse becau...

Страница 7: ...compressed air from the compressor head and the outlet tube when the air compressor reaches cut out pressure or is shut off The pressure release valve allows the motor to restart freely When the motor...

Страница 8: ...must be used use only a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the extension cord make sure the extension cord is in good conditio...

Страница 9: ...the same configuration as the plug See Fig 3 DO NOT USE AN ADAPTER Inspect the plug and cord before each use Do not use if there are signs of damage Improper grounding can result in electrical shock D...

Страница 10: ...rain water from air tank by opening drain cock valve on bottom of tank WATER WILL CONDENSE IN THE AIR TANK IF NOT DRAINED WATER WILL CORRODE AND WEAKEN THE AIR TANK CAUSING A RISK OF AIR TANK RUPTURE...

Страница 11: ...ll air tank pressure and allow unit to cool before doing any maintenance or repair Never operate the unit with the belt guard removed To ensure efficient operation and longer life of the air compresso...

Страница 12: ...otor Wiring Diagram The motor connection diagram is located on the side of motor STORAGE Before you store the air compressor make sure you do the following 1 Review the Maintenance section on the prec...

Страница 13: ...NOT OVER TIGHTEN Air leaks at or inside check valve Malfunctioning or dirty check valve A malfunctioning check valve results in a constant air leak at the pressure release valve when pressure is in th...

Страница 14: ...cessary Have checked by an Authorized Warranty Service Center Do not operate the compressor in the paint spray area See flammable vapor warning 1 Check fuse box for blown fuse and replace if necessary...

Страница 15: ...e in hose Check valve restricted Air leaks Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger...

Страница 16: ...tion of components within the air line Do not mix different styles of bodies plugs HOSE 3 8 I D HOSE Ideal for increasing working distance in high CFM applications 1 4 COIL HOSE Self retracting and li...

Страница 17: ...17 ENG NOTES...

Страница 18: ...erials or other contaminants Expendable items that become worn during normal use such as drain valves fuses filters belts air cleaners spark plugs engine oil and pump oil Cosmetic defects that do not...