CAUTION

 indicates a potentially

hazardous situation which, if not
avoided, 

may

 result in

  minor or

moderate injury.

This manual contains information that is important for you to know and understand. This infor-
mation relates to protecting 

YOUR

 

SAFETY

 and 

PREVENTING

 

EQUIPMENT PROBLEMS

. To

help you recognize this information, we use the symbols below. Please read the manual and
pay attention to these sections.

DANGER

 indicates an imminently

hazardous situation which, if not
avoided, will result in 

death or

serious injury.

CAUTION 

used without the safety

alert symbol indicates a potentially
hazardous situation which, if not
avoided,

  may  

result in

  property

damage.

WARNING 

indicates a potentially

hazardous situation which, if not
avoided, 

could

 result in 

death or

serious injury

.

Call our

 Toll Free Number 1-888-559-8550, 

to obtain the location of the nearest Autho-

rized Service Center for ordering repair parts and for warranty repairs.

When ordering repair parts from your local Authorized Service Center, always give the
following information:

• Model number of your compressor

• Part number and description of the item you wish to purchase

Retain Original Sales Receipt as Proof of Purchase for Warranty Repair Work.

SAFETY GUIDELINES - DEFINITIONS

IMPORTANT SAFETY INSTRUCTIONS

 When using electric tools, basic safety precautions

should always be followed to reduce the risk of fire, electric shock
and personal injury, including the following:

READ AND FOLLOW ALL INSTRUCTIONS.

This tool was designed for certain applications. Porter-Cable strongly recommends
that this tool NOT be modified and/or used for any application other than for which
it was designed.  If you have any questions relative to its application DO NOT use
the tool until you have written Porter-Cable and we have advised you.

Technical Service Manager
Porter-Cable Corporation
4825 Highway 45 North
P.O. Box 2468
Jackson, TN 38302-2468

Содержание CPF23400P

Страница 1: ...n the frame Record these numbers in the spaces below and retain for future reference Model No Type Serial No ESPA OL P GINA 19 FRAN AISE PAGE 37 IMPORTANT Please make certain that the person who is to...

Страница 2: ...e nearest Autho rized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following information Model...

Страница 3: ...IRE AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY HAZARD WHAT CAN HAPPEN HOW TO PREVE...

Страница 4: ...AIR FROM THE COMPRESSOR EITHER DIRECTLY OR FROM A BREATHING DEVICE CONNECTED TO THE COMPRESSOR WORK IN AN AREA WITH GOOD CROSS VENTILATION READ AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON THE LABEL...

Страница 5: ...AFTER OPERATION COMPRESSOR WILL REMAIN HOT FOR SEVERAL MINUTES AFTER OPERATION DO NOT REACH AROUND PROTECTIVE SHROUDS OR ATTEMPT MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL A PORTABLE COMPRESSOR C...

Страница 6: ...es Standards for Safety Porter Cable air compressors should be operated on not more than a 50 duty cycle This means an air compressor that pumps air more than 50 of one hour is considered misuse becau...

Страница 7: ...compressed air from the compressor head and the outlet tube when the air compressor reaches cut out pressure or is shut off The pressure release valve allows the motor to restart freely When the motor...

Страница 8: ...must be used use only a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the extension cord make sure the extension cord is in good conditio...

Страница 9: ...the same configuration as the plug See Fig 3 DO NOT USE AN ADAPTER Inspect the plug and cord before each use Do not use if there are signs of damage Improper grounding can result in electrical shock D...

Страница 10: ...rain water from air tank by opening drain cock valve on bottom of tank WATER WILL CONDENSE IN THE AIR TANK IF NOT DRAINED WATER WILL CORRODE AND WEAKEN THE AIR TANK CAUSING A RISK OF AIR TANK RUPTURE...

Страница 11: ...ll air tank pressure and allow unit to cool before doing any maintenance or repair Never operate the unit with the belt guard removed To ensure efficient operation and longer life of the air compresso...

Страница 12: ...otor Wiring Diagram The motor connection diagram is located on the side of motor STORAGE Before you store the air compressor make sure you do the following 1 Review the Maintenance section on the prec...

Страница 13: ...NOT OVER TIGHTEN Air leaks at or inside check valve Malfunctioning or dirty check valve A malfunctioning check valve results in a constant air leak at the pressure release valve when pressure is in th...

Страница 14: ...cessary Have checked by an Authorized Warranty Service Center Do not operate the compressor in the paint spray area See flammable vapor warning 1 Check fuse box for blown fuse and replace if necessary...

Страница 15: ...e in hose Check valve restricted Air leaks Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger...

Страница 16: ...tion of components within the air line Do not mix different styles of bodies plugs HOSE 3 8 I D HOSE Ideal for increasing working distance in high CFM applications 1 4 COIL HOSE Self retracting and li...

Страница 17: ...17 ENG NOTES...

Страница 18: ...erials or other contaminants Expendable items that become worn during normal use such as drain valves fuses filters belts air cleaners spark plugs engine oil and pump oil Cosmetic defects that do not...

Отзывы: