Sharpener Unit Safety

•  Do not force the power tool. Use the correct power tool for your application. The correct 

power tool will do the job better and safer at the rate for which it was designed.

 

Do not use the power tool if the switch does not turn it on and off. Any power 
tool that cannot be controlled with the switch is dangerous and must 

  be repaired.

•  Disconnect the plug from the power source and/or the battery pack from the power 

tool before making any adjustments, changing accessories, or storing power tools. Such 
preventive safety measures reduce the risk of starting the power tool accidentally.

• 

WARNING!

 The adjusting nut must be tightened before starting to work with the 

machine.

•  Maintain power tools. Check for misalignment or binding of moving parts, breakage of 

parts and any other condition that may affect the power tool’s operation. If damaged, 
have the power tool repaired before use. Many accidents are caused by poorly 
maintained power tools.

• 

WARNING!

 Always use the protective shields on the machine. Do not remove the 

transparent front guard. If the transparent front guard is damaged or missing, re-turn 
tool to authorized service station for replacement.

•  Do not use a damaged grinding wheel. Before each use inspect the wheel for chips 

and cracks or excess wear. The grinding wheel must be properly mounted and turn 
freely. Perform a test run for at least 30 seconds without load. Do not use damaged, 
out of round or vibrating grinding wheels.

•  Immediately switch off the machine in case of considerable vibrations or if other 

malfunctions occur. Check the machine in order to find out the cause.

•  The outside diameter and the thickness of your accessory must be within the capacity 

rating of your power tool.

!

Safety Warnings for Chainsaw Sharpener

Flexisharp instructions.indd   8

11/07/2018   13:24

Содержание FlexiSharp

Страница 1: ...ead and fully understand the instructions before operating the Portek Flexisharp Operators Handbook portek co uk Li ion Battery Powered Chainsaw Sharpener Flexisharp instructions indd 1 11 07 2018 13...

Страница 2: ...s and can perform without restrictions or have received appropriate instructions Respect technical data and safety precautions Do not use this product in any other way as stated for normal use Not obs...

Страница 3: ...according to the regulation and requirement of local council Do not dispose of batteries in household waste fire risk of explosion or water Damaged batteries may damage the environment and your health...

Страница 4: ...4 Flexisharp 1 2 3 6 4 7 13 9 14 10 8 5 Flexisharp instructions indd 4 11 07 2018 13 24...

Страница 5: ...g light 11 Battery 12 Charger 13 Grinding wheel cover 14 Grinding wheel shield Contents CONTENTS Before you start 2 Safety introduction 3 Flexisharp main features 4 5 General safety information 6 7 Sh...

Страница 6: ...operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes 2 Electrical safety Do not expose p...

Страница 7: ...d ear defenders Wear a hairnet if you have long hair It is recommended to wear gloves sturdy non slipping shoes and apron Prevent unintentional starting Ensure the switch is in the off before connecti...

Страница 8: ...n that may affect the power tool s operation If damaged have the power tool repaired before use Many accidents are caused by poorly maintained power tools WARNING Always use the protective shields on...

Страница 9: ...s avoid contact with the fluid If contact occurs flush the affected area with water Seek additional medical help if any of the fluid gets into your eyes Escaping battery fluid may cause skin irritatio...

Страница 10: ...torage only after it has been fully charged Protect batteries and the tool from overloads Overloads will quickly result in over heating and cell damage inside the battery housing without this overheat...

Страница 11: ...ging and cell damage Do not leave batteries in the charger for days on end Never use or charge batteries if you suspect that the last time they were charged was more than 12 months previously There is...

Страница 12: ...uipment pressing the pushlock button downwards to do so 2 Check that your mains voltage is the same as that marked on the rating plate of the battery charger To ensure that the battery pack provides l...

Страница 13: ...ull the cable through the chain guide clamping piece and replace the plastic tension nut Work Surface Mounting 3 Place the unit base on to a solid level work surface Ensure the base extends out far en...

Страница 14: ...position while you tighten the screw so that the grinding wheel will only go down to that point fix this position with the locking screw 5 Switch ON the Flexisharp by pressing firmly Use the handle t...

Страница 15: ...g wheel and replace with a new one Tighten the fixing nut but do not over tighten over tightening may cause the wheel to crack or break Only use grinding wheels with an outer diameter of 108mm and inn...

Страница 16: ...2 2 27 Baffle 1 28 Screw ST5 5 20 3 29 Wash 1 30 Steel Bushing 1 PART NO DESCRIPTION QTY 31 Swing Arm 1 32 Chain Stop 1 33 Washer 4 1 34 Screw M8 x45 1 35 Chain Saw Frame 1 36 Screw ST4 8 10 2 37 Inne...

Страница 17: ...17 Walking forward take slow sweeping movements to clear long grass and brush with ease WEAR SAFETY PROTECTION AT ALL TIMES Parts List Flexisharp instructions indd 17 11 07 2018 13 24...

Страница 18: ...local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get i...

Страница 19: ...ith new switch LED light is bright 1 Connection terminal 1 Replace the machine cannot work loose connection terminal 2 Motor damaged 2 Replace a new motor LED light isn t bright 1 Connection terminal...

Страница 20: ...EC Council Machinery Directive Annex II Designation of Machinery Portek Chainsaw Sharpener Relevant EC Council Directives 2006 42 EC Machinery Directive 2014 30 EU Electromagnetic Compatibility Direct...

Отзывы: