SIMULTANEOUS PAIRS
§
When wiring controls for use as a simultaneous pair, all required inputs need to be sync’d (connected) between Door #1 and Door
#2 (shown as dotted lines in above diagram).
§
Example shown above: Push plates are connected to inputs 8, 10 and 11 at door #1 and are connected via sync line to Door #2.
§
When using pairs of controls, N.C. inputs 12, 13 and 14 may be sync’d to each other, OR each control may have its own jumpers
installed. If any of these inputs are required for the application, the jumper will be removed for the respective input – in place of the
jumper, a N.C. switching circuit will be connected to Door #1, and a sync line will be connected to Door #2.
§
For simultaneous pairs, PORTALP provides a dual harness for the On-Off-Hold switch. Each plug-in connector for the control is wired
in parallel to the On-Off-Hold switch located in the header end-cap. One switch will control both doors.
§
All control adjustments (speed & time delay) must be made independently at each control.
§
All dip switches at each control must be set independently and must match between controls.
§
When using the TAP programmer, settings must be made independently at each control and must match between controls.