INSTALLATION
GUIDE
POWER ON
&
INDICATIONS
Upon applying power, observe the above LED’s.
NORMAL OPERATION: DL3 will come on steady and then begin flashing after a few seconds.
FAULTY OPERATION; DL2 will be flashing
RED
. This indicates…
§
An error condition exists – correct as necessary
§
Operator requires setup – launch a setup and proceed accordingly
NOTE:
DL4 will illuminate yellow anytime a change has been made to the control, such as a speed or time adjustment.
Momentarily press on SW1 to acknowledge the change and extinguish the yellow LED.
HELPFUL NOTES:
§
Speed and time adjustment changes will not take effect until the door closes fully after the adjustment has been made.
§
Hold Open time affects the delay following activation from input 10, 11, and 13.
§
When Dip Switch 5 is ON, the blue speed and time potentiometers are disabled and will have no effect.
DL1 :
GREEN
USB CONNECTION
DL2:
FLASHING
RED
LED
DL3:
BLUE
5V POWER SUPPLY
DL4:
BOARD VALUES DIFFER FROM DIP SWITCHES
(PRESS SW1 MOMENTARILY TO EXTINGUISH YELLOW LED)
WWW.PORTALP.COM
|
23
Automatic Doors & Building Access Control
SW10
(Full Power) & S
W19
(Low Energy)