7.9
Troubleshooting
Always disconnect the pump in cause of fault!
Malfunction
Possible cause
Remedy
No
suct
ion
No
pu
mp
ing
L
o
w
f
low
r
ate
L
o
w
ho
se
life
Hig
h
pu
mp
t
emp
er
atu
re
P
u
mp
do
es
no
t st
ar
t
Hig
h
pip
e wo
rk
vibr
atin
g
X
X
X
Maximum suction height exceeded
Check suction height
X
X
X
Leaking of suction line
Check suction line and
connections
X
X
Blocked pressure line
Check pressure line
X
Blocked pressure line
Check pressure line
X
X
Wear of rollers / inserts
Replace
X
X
Insufficient / no grease on hose
→ 7. Maintenance/Service
X
X
Medium temperature too high
Note permissible temperature
X
Incorrect hose installation
→ 6.4 Installing the pump hose
X
High pump speed
Determine max. flow rate to the
medium
X
X
High viscosity of medium
Determine max. flow rate to the
medium
X
Undersized suction and pressure line
Calculate pressure loss
X
Geometry of suction and pressure
line
e.g. do not use a 90° angle
X
Hose material not suitable for
medium
Consult the manufacuterer
X
Sharp-edged particles in the medium
Provide suction filter
X
Sedimentation of medium on
pressure side
Check pressure line
X
Motor protection started
Check
X
Insufficient fastening
Check
X
Pulsation too high
Use pulsation damper
X
No uncoupling of pump to the pipe
system
Use compensator