5.1
Detector for hose leakages
The hose leakage detector is for a continuous monitoring in order to avoid unnoticed hose
leakages.
Functional description
In case of a hose leakage the pump can be switched off and an alarm (horn/signal lamp)
can be activated. This is only possible when using a motor contactor.
Safe function is only guaranteed with electrically conductive fluids.
The following mentionned detectors for hose leakages are available:
Part no. 93-000-055
Detecor for hose leackages for operating the pumps in non-hazardous locations and for
electrically conductive media.
Part no. 93-000-045
Detector for hose leackages with PLC sensor for operating the pumps in non-hazardous
locations and for electrically conductive and non-conductive media.
Part no. 93-000-009
Detector for hose leackages for operating the pumps in hazardous locations and for
electrically conductive and non-conductive media.
If other sensors are used, the operator is responsible for checking their
suitability.
Rear view of pump head