Operation &
Maintenance Manual
Pump
RW
782-001-GB
HSC
08-W36
Edition 4
19/32
7.5
Oil level
7.5.1 RW 20
Put the pump in a horizontal position so that the 2
hexagonal socket screws are on top (see fig.7.4).
Unscrew the level plug (1) and the vent plug (2).
The oil level should be at the lower side of the openings
(see drawing).
By turning the pump a bit this should be visible.
If not so fill up to the right level.
Always use the right kind of oil !
It is possible that your pump is fitted
with 3 plugs.
For oil check see 7.5.2
7.5.2 RW 40
Put the pump in a horizontal position so that 2
hexagonal socket screws are on top and one at
the bottom (see fig.7.5).
Unscrew the level plug (1) and the vent plug (2).
The oil level should be at the lower side of the openings
(see drawing). By turning the pump a bit this should be
visible.
If not so fill up to the right level.
Always use the right kind of oil !
7.5.3 RW 60 / RW 80
Put the pump in a vertical position.
Unscrew the M20 oil pug (1) which can be found at the
opposite side of the cable entry box
(see fig. 7.6).
The oil level should be at the lower side of the opening.
If not so fill up to the right level.
Always use the right kind of oil !
Ensure that the pump is fully supported
to prevent it from falling over !
Fig. 7.4
Fig. 7.5
Fig. 7.6
www.robotpompen-onderdelen.nl
T +31(0)294-457712