background image

17 

 

6.5 

Advanced settings “ADVANCED“ 

By selecting the menu item 

”ADVANCED“

,

 

general settings can be made on the device and device-specific data 

can be read out.    
 

Programming sequence and display: 

 
 
 

 

LANGUAGE

  

= Language selection (English, Italian, Spanish or French) 

FW VERSION

  

= Displays the firmware version of the device 

SERIAL NUMBER 

= Displays the serial number of the devices 

FORMAT CARD  

= Formatting the SD card

 

 
 

6.6 Load settings from the SD card 

“LOAD SD PRESET“ 

By selecting the menu item 

”LOAD SD PRESET“

,

 

a saved configuration can be reloaded from the SD card to the 

device.  
 

Programming sequence and display: 

 
 
 

 

 

6.7 Save settings to the SD card 

“SAVE SD PRESET“ 

By selecting the menu item 

”SAVE SD PRESET“

, a device configuration can be saved on the SD card.   

It is recommended to make a backup on the SD card after every change to the settings. In this menu

,

 it is also 

possible to delete all saved settings from the SD card. To do this, select the submenu 

”DELETE ALL“

 with the 

rotary button and confirm by pressing it.  
 

Programming sequence and display: 

 
 
 
 

6.8 Activation of passwor

d protection “Exit“ 

By selecting the menu item 

”Exit“

, password protection can be created and the setting menu can be exited.   

 

Programming sequence and display: 

 
 
 

 

 

 

 

 
 
 
 
 

If the device password is not available, the device can be accessed with the master password 

50

 

 

 

 
 

 

Selection of the menu 

ADVANCED

 via short press of the rotary button 

 

 

Load of a configuration from the SD card 

 

Save of a configuration on the SD card 

Selection of the menu 

Exit

 via short press of the rotary button - activation of password 

protection via selection of the submenu 

LOCK

 

 

Entry of the password 
ATTENTION - device is shut down and restarted with password protection! 

 

Deactivation of password protection 

Содержание 5903550

Страница 1: ...1 TSM 32 HD SAT ZF Konverter SAT IF Converter Bedienungsanleitung Operating manual 0902401 V1...

Страница 2: ...erung der Ausgangssignale OUTPUT ______________________________ 8 6 5 Erweiterte Einstellungen ADVANCED _______________________________________ 9 6 6 Laden der Einstellung von der SD Karte LOAD SD PRE...

Страница 3: ...zlich kann der Erdungsanschluss am Ger t genutzt werden Ger te im Handbereich sind untereinander in den Potentialausgleich einzubinden Ein Betrieb ohne Schutzleiteranschluss Ger teerdung oder Potentia...

Страница 4: ...versorgten Anschl ssen erst f r eine DC Spannungsentkopplung sorgen bzw 75 Ohm Abschlusswiderst nde verwenden mit integrierter DC Entkopplung Achtung Diese Baugruppe enth lt ESD Bauteile ESD Elektrost...

Страница 5: ...orhandenes SAT taugliches Koaxial Verteilnetz eingespeist werden Hierbei ist es nicht relevant ob es sich um ein Netz mit Stern Baum oder gemischter Struktur handelt Die Teilnehmer k nnen alle auf den...

Страница 6: ...installiert werden Von dieser kann eine bestehende Konfiguration auf den Konverter geladen oder die vorhandene Konfiguration auf der SD Karte gesichert werden Der SAT Konverter wird von einem externen...

Страница 7: ...UATTRO HIGH 1100 MHz 2150 MHz Qhi Whi QUATTRO HIGH 1100 MHz 2150 MHz WIDEBAND HIGH 1290 MHz 2340 MHz Whi Qhi WIDEBAND HIGH 1290 MHz 2340 MHz QUATTRO HIGH 1100 MHz 2150 MHz Whi Whi WIDEBAND HIGH 1290 M...

Страница 8: ...kurzes Dr cken des Drehknopfes Untermen ist aktiviert DC Auswahl der LNB Schaltsignale OFF 13V Vertikal Low Band 13V TONE Vertikal High Band 18V Horizontal Low Band 18V TONE Horizontal High Band ADD T...

Страница 9: ...mpfohlen nach jeder nderung an der Einstellung eine Sicherung auf der SD Karte vorzunehmen In diesem Men ist es auch m glich alle gesicherten Einstellungen von der SD Karte zu l schen Dazu mit dem Dre...

Страница 10: ...ng of the output signals OUTPUT ________________________________ 16 6 5 Advanced settings ADVANCED ____________________________________________ 17 6 6 Load settings from the SD card LOAD SD PRESET ___...

Страница 11: ...onnection on the device can be used Other devices within touching distance are to be integrated in the equipotential bonding Operation without a protective conductor connection device grounding or equ...

Страница 12: ...ections should be terminated with 75 Ohm terminating resistors For DC supplied connections DC voltage decoupling must be used or use 75 Ohm terminating resistors with integrated DC decoupling Attentio...

Страница 13: ...to an existing SAT compatible coaxial distribution network It is not relevant whether it is a network with star tree or mixed structure The subscribers can receive all programs on the transponders wit...

Страница 14: ...lot From this an existing configuration can be loaded onto the converter or the existing configuration c from the device can be saved on the SD card The SAT converter is powered by an external 12V pow...

Страница 15: ...0 MHz Qhi Whi QUATTRO HIGH 1100 MHz 2150 MHz WIDEBAND HIGH 1290 MHz 2340 MHz Whi Qhi WIDEBAND HIGH 1290 MHz 2340 MHz QUATTRO HIGH 1100 MHz 2150 MHz Whi Whi WIDEBAND HIGH 1290 MHz 2340 MHz WIDEBAND HIG...

Страница 16: ...button sub menu is activated DC selection of the LNB switching signals OFF 13V vertical low band 13V TONE vertical high band 18V horizontal low band 18V TONE horizontal high band ADD Transponder acti...

Страница 17: ...o make a backup on the SD card after every change to the settings In this menu it is also possible to delete all saved settings from the SD card To do this select the submenu DELETE ALL with the rotar...

Страница 18: ...level Transponder Anzahl der Transponder Number of transponders 32 Konvertierung convertion Bandbreite Bandwidth 1 64 MHz 1 MHz Schritte 1 MHz steps Selektivit t Selectivity 35 dB 1 MHz R ckflussd mp...

Страница 19: ...2 3 4 MHz MHz MHz 11 1 2 3 4 MHz MHz MHz 12 1 2 3 4 MHz MHz MHz 13 1 2 3 4 MHz MHz MHz 14 1 2 3 4 MHz MHz MHz 15 1 2 3 4 MHz MHz MHz 16 1 2 3 4 MHz MHz MHz 17 1 2 3 4 MHz MHz MHz 18 1 2 3 4 MHz MHz M...

Страница 20: ...hme H Q Order department 49 0 70 81 1702 0 Technische Hotline Technical hotline 49 0 70 81 1702 0 Telefax 49 0 70 81 1702 50 Internet http www polytron de Email info polytron de Technische nderungen v...

Отзывы: