16
6.3 Manually programming
“INPUT SAT 1 - 4“
Via the menu item
“INPUT SAT 1 - 4“
the manual programming of the transponders can be done. In this menu, the
inputs 1 to 4 are selected and the desired transponders will be set on the input and output side. The number of
transponders is limited to a maximum of 32.
If the message “MAXIMUM TRANSP. REACHED“ is
displayed, the
maximum converter capacity has been reached.
Programming sequence and display:
If it is necessary to delete a programmed transponder, this can be done by selecting the relevant transponder
”TRANSP: 17“
and pressing the rotary button for 3 seconds.
6.4 Programming of the output signal
s “OUTPUT“
By selecting the menu item
”OUTPUT“
, the transponder output level in dBµV can be programmed. In addition, the
signal can be pre-equalized in the range of 0 - 15 dB. The value shown on the display is the output level of the
transponder with the highest frequency. If many transponders are implemented, a level reduction may be necessary.
Programming sequence and display:
Selection of the desired
input SAT 1 … SAT 4 and confirmation via short
press of the rotary button
sub menu is activated
DC
= selection of the LNB switching signals:
OFF,
13V (vertical low band), 13V+TONE (vertical high band)
18V (horizontal low band), 18V+TONE (horizontal high band)
ADD Transponder
= activation of the submenu for programming the transponders
Entry of the input and output frequency of the transponder between 290 MHz and 2340 MHz
Entry of the bandwidth 1 - 64 MHz (1 MHz steps) and the input level of the transponder will be displayed
After all entries for transponder 1 have been made, please scroll to the menu item
TRANSP: 1
and
confirm by pressing the rotary button
save the settings for transponder 1
By selecting
ADD TRANSPONDER
,
further transponders from input SAT 1 can be added - maximum 32 over 4
SAT polarisations - all transponders are programmed according to the programming of transponder 1
To program transponders of other SAT inputs, scroll to
INPUT SAT 1
and select the desired input by turning the
rotary button and confirm by pressing it - all transponders are programmed in the same way of programming
INPUT SAT 1
Selection of the menu
OUTPUT
via short press of the rotary button
Definition of the output level in the range of 89 - 112 dBµV (1 dB steps) or fixed
selection
of 70 dBµV or 83 dBµV for optical systems
Definition of the pre-equalization in the range of 0 - 15 dB