P9

 Weekend (second house)

  0  1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23

Mo

  0  1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23

Tu

  0  1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23

We

  0  1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23

Th

  0  1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23

Fr

  0  1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23

Sa

  0  1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23

Su

Measured 

Temperature 

Precision: 

0.1°C

Environmental 

Operating Temperature: 

0°C - 40°C 

Shipping and Storage 

Temperature: 

-10°C to +50°C

Setting Temperature 

Range 

Comfort, Reduced: 

5°C to 35°C 

 

by 0.5°C step 

Holiday (Antifreeze): 

7°C 

10°C (adjustable): 

0.5°C to 20°C 

Timer: 

5°C to 35°C

Regulation 

Characteristics: 

Hysteresis of 0.5°C

Electrical 

Protection: 

Class II - IP30

Power Supply: 

2 AAA LR03 1.5V 

Alkaline 

Operating Life: 

2 Years

Output: 

2 Points Contact  

 

 

(Free Contact) 

 

Relay 5 Amps 250Vac

Optional External 

Sensor: 

10k ohms at 25°C

9. Technical details

10. Fault Diagnostics

My thermostat doesn’t start 

  Battery 

- Check if the protection sticker

 

Problem

 

  on the batteries is removed.

   

- Check the orientation of the batteries. 

   

- Check the charge of the batteries.

My thermostat LED, blinks in red 

  Problem 

 

The logo blinks (ambient sensor)

 

on Sensors

 

 

- Contact your installer. 

   

 

The logo blinks (floor sensor).

   

 

-  Check the connection 

of the sensor.

   

 

-  Disconnect the sensor, and check  

it with an ohmmeter (the value 

must be around 10kohms).

  Battery  

 

The logo blinks (batteries)

 

level is low

   

- Replace the batteries.

My thermostat seems work correctly but 

the temperature in the room was never 

in accordance with the program

  Program 

- Check the clock.

   

-  Check the difference between 

Comfort and Setback temperature 

is not too high?

   

-  Contact your installer, to check 

and adjust the calibration.  

8.  Pre-set  

Programs (9)   

Содержание PBPRP

Страница 1: ...Programmable Room Thermostat User Guide PBPRP PBPRP RF PBPRP2 SEPTEMBER 2010 EFFECTIVE 1ST SEPTEMBER 2010 September 2010...

Страница 2: ...Programs 05 4 1 Creating a user defined program 06 5 Room temperature settings 07 5 1 Comfort temperature setting 07 5 2 Setback temperature setting 07 6 Operating menus 08 6 1 Automatic operation 08...

Страница 3: ...ed the temperature the room will not fall below This is to assist the response time of the heating system For solid floor systems it is recommended that the Setback temperature is set no more than 4 C...

Страница 4: ...programming 14 Key lock indicator 2 First Time Installation This section will guide you to starting your thermostat for the first time 2 1 Installing Batteries Open the two side covers and insert the...

Страница 5: ...s OK to make the P1 P9 adjustable Use the or keys to choose P1 to P9 or U1 to U4 User Defined Programs Select and validate with OK to return to Auto 4 User Defined Programs U1 to U4 Pictograms to help...

Страница 6: ...1 Monday Once you have pressed the key the following display will appear Adjust the hour of the first step of the program with or Press OK to validate and jump to the following step The pictogram will...

Страница 7: ...of the week Sunday Press OK on the last day to SAVE your program 5 Room Temperature Settings In order to set room temperatures to work with the program you have selected or created you will need to a...

Страница 8: ...unction default value 22 C The logo will be blink and the number of hours days left is displayed until the end of the period If you want to stop the timer function before the end of the duration adjus...

Страница 9: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Sa 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Su P3 Day Weekend 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22...

Страница 10: ...9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Sa 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Su P7 7H 19H Office P7 7H 19H Office 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20...

Страница 11: ...ection Class II IP30 Power Supply 2 AAA LR03 1 5V Alkaline Operating Life 2 Years Output 2 Points Contact Free Contact Relay 5 Amps 250Vac Optional External Sensor 10k ohms at 25 C 9 Technical details...

Страница 12: ...te Only the heating element managed by the thermostat must be run during the complete step of the calibration 06 EXTS Instananeous value of floor sensor 08 HG Frost protection temperature 10deg C 09 I...

Страница 13: ...rnon Glasgow G32 8XZ Tel 0141 778 8822 Fax 0141 778 2703 Dromore Road Lurgan Craigavon Co Armagh BT66 7HL Tel 028 38 881270 Fax 028 38 882344 www polypipe com Underfloor heating systems trade website...

Отзывы: