OVERVIEW

The Polypipe range of Programmable Room Thermostats (PBPRP & PBPRP RF) 

provides time and temperature control for a space of up to 40m

2

The hardwired PBPRP, is compatible with the wet room sensor PB23020 and  

should be installed 1.2m above floor level and away from direct heat sources. 

Wiring details are provided in the additional documentation.
The PBPRP RF is suppled with an RF receiver unit. Details on registering the 

thermostat with the receiver unit are provided in the additional documentation.
This user guide provides user settings and programming details. These, and the 

advanced settings, can also be downloaded in A4 format from www.ufch.com

Please Read Before 

Programming Your 

Thermostat

Temperature settings 

The Programmable Room Thermostat operates at 2 different 
temperatures:

Comfort 

- When the space is occupied - the desired temperature 

Setback

 - When the space is unoccupied - the temperature the 

room will not fall below

This is to assist the response time of the heating system.  
For solid floor systems it is recommended that the Setback 
temperature is set no more than 4°C lower than the Comfort 
temperature. You may find that other systems can be set with a 
higher differential.

Time Settings 

The room thermostats are preset with a function called Optimum 
Start (ITCS in the menu function). This means that you do not 
need to adjust each room for the warm up time from Setback to 
Comfort. The On Time in the pre-set programs, or the start time 
as defined by users in the User Defined programs, the time by 
which the room will be at the Comfort temperature by, not the 
time the heating will start to operate.

Each thermostat will learn the warm up time of each room, start 
the heating at a time to achieve Comfort by the time required, 
and self adjust for changes in outside temperature.

When this function is operating, i.e. the thermostat is heating 
prior to the actual time setting, the          symbol will blink.

This function can be de-activated in the Installer Menu  
(see page 9).

Содержание PBPRP

Страница 1: ...Programmable Room Thermostat User Guide PBPRP PBPRP RF PBPRP2 SEPTEMBER 2010 EFFECTIVE 1ST SEPTEMBER 2010 September 2010...

Страница 2: ...Programs 05 4 1 Creating a user defined program 06 5 Room temperature settings 07 5 1 Comfort temperature setting 07 5 2 Setback temperature setting 07 6 Operating menus 08 6 1 Automatic operation 08...

Страница 3: ...ed the temperature the room will not fall below This is to assist the response time of the heating system For solid floor systems it is recommended that the Setback temperature is set no more than 4 C...

Страница 4: ...programming 14 Key lock indicator 2 First Time Installation This section will guide you to starting your thermostat for the first time 2 1 Installing Batteries Open the two side covers and insert the...

Страница 5: ...s OK to make the P1 P9 adjustable Use the or keys to choose P1 to P9 or U1 to U4 User Defined Programs Select and validate with OK to return to Auto 4 User Defined Programs U1 to U4 Pictograms to help...

Страница 6: ...1 Monday Once you have pressed the key the following display will appear Adjust the hour of the first step of the program with or Press OK to validate and jump to the following step The pictogram will...

Страница 7: ...of the week Sunday Press OK on the last day to SAVE your program 5 Room Temperature Settings In order to set room temperatures to work with the program you have selected or created you will need to a...

Страница 8: ...unction default value 22 C The logo will be blink and the number of hours days left is displayed until the end of the period If you want to stop the timer function before the end of the duration adjus...

Страница 9: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Sa 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Su P3 Day Weekend 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22...

Страница 10: ...9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Sa 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Su P7 7H 19H Office P7 7H 19H Office 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20...

Страница 11: ...ection Class II IP30 Power Supply 2 AAA LR03 1 5V Alkaline Operating Life 2 Years Output 2 Points Contact Free Contact Relay 5 Amps 250Vac Optional External Sensor 10k ohms at 25 C 9 Technical details...

Страница 12: ...te Only the heating element managed by the thermostat must be run during the complete step of the calibration 06 EXTS Instananeous value of floor sensor 08 HG Frost protection temperature 10deg C 09 I...

Страница 13: ...rnon Glasgow G32 8XZ Tel 0141 778 8822 Fax 0141 778 2703 Dromore Road Lurgan Craigavon Co Armagh BT66 7HL Tel 028 38 881270 Fax 028 38 882344 www polypipe com Underfloor heating systems trade website...

Отзывы: