13.Intervention time adjustment
18
SANDOR WS SMA
POLITEC | INSTALLATION MANUAL - VER.3.1
On the SK WS RX motherboard there is a potentiometer to adjust the INTERVENTION TIME.
In particular, it is possible to set the barrier for rapid (crossing while running) or slow (crossing
while walking) alarms.
By adjusting the potentiometer anticlockwise, the intervention time is increased up to 500ms.In
this condition, the alarm of a person crossing the barrier while walking is guaranteed, with the
advantage of excluding the possibility of any false alarms (e.g. animal crossing).
By adjusting the potentiometer clockwise, the intervention time decreases down to 50ms.In this
condition, the alarm of a person crossing the barrier running at maximum speed is guaranteed.
ALARM
ALARM
Содержание SANDOR WS SMA
Страница 27: ......
Страница 28: ...For technical support contact your security systems distributor...