background image

3.General warnings

4

SANDOR WS SMA

POLITEC | INSTALLATION MANUAL - VER.3.1

This installation manual contains important information regarding safety for installation: it is 
necessary to read all the instructions before proceeding with the installation.

Keep this manual for future use. 

If you have any questions or doubts during installation, do not carry out any operations and contact
the distributor's support service.

Use of these products for purposes other than those specified in these instructions is prohibited.

You must not make any changes to the components of the product unless stated in the manual in
order not to void the warranty; such operations can only lead to malfunctions; Politec assumes no
liability for malfunctions or damage due to modified products.

Depending on the specific situation of use, check for the need for additional devices: detectors or
signalling devices.

During installation, mounting and use of the product, make sure no foreign objects (solids, metals
or liquids) are able to penetrate inside the open devices.

Manufacturer's liability:Politec assumes no liability for failures resulting from incorrect installation;
lack of maintenance, incorrect assembly or use.

Politec is also not liable for incorrect or incomplete operation of the product or failure to detect
intrusion.

Warranty (summary of conditions):Politec guarantees its products for a period of 2 years from the
production date.The warranty is applied to those purchasing directly from Politec; there is no
warranty for the end user who, in the event of breakdowns or faults, must contact the installer or
dealer.

The warranty excludes aesthetic parts as well as parts subject to normal wear and parts subject to
normal consumption such as batteries and accumulators.

3.1 Additional warnings for devices powered by mains voltage

This manual is intended only for technical personnel qualified to install such devices.

Assessing the hazards that may occur during installation and use of the system, in order to achieve
complete safety, it is necessary that installation takes place in full compliance with applicable laws,
methods, rules and regulations.

Before accessing the internal terminals of the product, it is necessary to disconnect all the power
circuits.

If automatic circuit breakers or fuses trip, before resetting them it is necessary to identify the fault
and repair it.

3.2 Installation warnings

Check that all the material to be used is in excellent condition and suitable for use.

Before proceeding with the installation, check the environmental class of the products in the
"technical specifications" chapter.

Check, by comparing with the values shown in the paragraph "technical specifications", that the
range of the devices is equal to or lower than the physical distance between the barriers.

Check that the barrier is positioned in areas protected against potential impact, in flat areas and on
fixed supports to avoid oscillations.

Do not place the system components close to heat sources as they could be damaged.

Each barrier has its own operating principle: check the instructions for choosing the right position
in the respective instruction manual.

Содержание SANDOR WS SMA

Страница 1: ...PRODUCT SANDOR WS SANDOR WS SMA Product code SANDOR WS SMA DOUBLE OPTIC PERIMETER BARRIER INSTALLATION AND MOUNTING MANUAL VERSION 3 1...

Страница 2: ...t 7 6 1 Assembly and installation 6 2 Cable pit positioning 7 Evaluations before installation 9 7 1 Introduction to barriers 8 Barrier positioning 10 8 1 Precautions before installation 9 Installation...

Страница 3: ...n the event of simultaneous interruption of two superimposed beams N B These barriers use optical synchronism The receiver must see ONLY and exclusively its transmitter MUST NOT see signals from other...

Страница 4: ...m Politec there is no warranty for the end user who in the event of breakdowns or faults must contact the installer or dealer The warranty excludes aesthetic parts as well as parts subject to normal w...

Страница 5: ...kage contains the following components and accessories When opening the package check that everything has been included No COMPONENT 1 Aluminium profile 2 Caps 3 Transmitter Receiver optics 4 SK WS RX...

Страница 6: ...iversal circuit board housing insert and connect the radio transmitter and connect it to the barrier receiver board c Power up the barriers and program them d Test barrier operation e Place without fi...

Страница 7: ...its range of action trees plants or objects that can swing or move with the wind or rain Position the barrier so that sunlight does not hit it directly near the RX sensors In any case it is necessary...

Страница 8: ...rings and cable glands Wall mounting with SAN PL The SAN PL brackets also allow fixing to the wall in a very simple way as seen in the figure It is recommended to use these when protecting windows do...

Страница 9: ...enerating a kind of barrier invisible to the human eye 2 50 m 2 m View from above TX RX Signal interruption ALARM An active infrared barrier can contain multiple transmitting and receiving stages insi...

Страница 10: ...surfaces such as walls or anything that can attenuate the signal DO NOT place the barriers if there are plants bushes or fixed objects in the range that obstruct the signal and create grey areas Leav...

Страница 11: ...tself very well to single barrier systems and for the protection of facades as well as in the open field following the recommended distances To avoid interference between barriers position the columns...

Страница 12: ...0 V or 3 6 V via the selector BL BATTERY LOW Low battery signal output due to the opening from the negative of an open collector NC SL SIGNAL LOW Fog disqualification signal output given by the closi...

Страница 13: ...3 4 Battery connectors 3 6 V 19 Ah P S The second battery is optional 1 2 HTR Heater power supply 24V 12V only from external source 3 4 NN Not used TERMINAL BOARD with 4 ports The tamper opening infor...

Страница 14: ...t of the lens Vertical orientation Horizontal orientation JOINT LOCKING SCREW N B Tighten the joint locking screw after the adjustment 12 1 Calibration using SMA system It is possible to improve the c...

Страница 15: ...for about 3 seconds or until the orange TEST LED lights up Press the TEST button on the corresponding RX optic for about 3 seconds or until the orange TEST LED lights up in addition to the intermitte...

Страница 16: ...a FULL rotation on the horizontal axis of the RECEIVER optic thereby performing the SCANNING of the optical signal This operation is very useful to understand if the alignment of the optics is taking...

Страница 17: ...r infrared source that must be turned off and eliminated At the end of the operation remove the screen which acts as an attenuator making sure to have found the optimal value RX 1 TX 1 RX 2 TX 2 RX 3...

Страница 18: ...ing alarms By adjusting the potentiometer anticlockwise the intervention time is increased up to 500ms In this condition the alarm of a person crossing the barrier while walking is guaranteed with the...

Страница 19: ...ment The TEST LED starts flashing 2 Not used 3 BEAM ON Activates all transmitters in test during the alignment phase DIP 1 ON Steady TEST LED 4 BEAM OFF Deactivates all the transmitters during the ali...

Страница 20: ...L When ON the ANTI CRAWL function is activated meaning that the blocking of the RX1 beam the first at the bottom for at least 2 sec causes the alarm condition regardless of whether it was previously s...

Страница 21: ...sses are already set by default and shown here in the maximum configuration N B The barrier can result in an alarm even if the WEAK LED SIGNAL is off The cause may be the lack of synchronism or a misa...

Страница 22: ...TION MANUAL VER 3 1 14 4 Transmitter optic Tamper N B The settings relating to the addresses are already set by default and shown here in the maximum configuration Test LED Test button 1 2 3 4 5 6 1 2...

Страница 23: ...Random REMOTE CONTROL AND Random ALARM OUTPUT NC relay contact DISQUALIFICATION OUTPUT Automatic if enabled with external signalling O C NO to GND ANTIMASK OUTPUT Automatic if enabled with external si...

Страница 24: ...obscure each beam individually finding the one that does not generate the general alarm this beam is not aligned Make sure that the connectors are well inserted and that the DIP configuration is corre...

Страница 25: ...turbances use a shielded cable with the braid to the negative of the terminal board as the connection between the wireless transmitter and the barrier The system goes into disqualification even in the...

Страница 26: ...regulations in force in your area Warning Some parts of the products may contain polluting or dangerous substances which if dispersed in the environment could result in harmful effects on the environ...

Страница 27: ......

Страница 28: ...For technical support contact your security systems distributor...

Отзывы: