16
SANDOR WS SMA
POLITEC | INSTALLATION MANUAL - VER.3.1
•
The maximum alignment condition will be reached when the high-intensity LEDs are on steady
and the buzzer will emit a continuous sound, for this reason, it may be necessary to make minor
adjustments also on the RX optic.
TX
RX
TX
RX
•
Orient the TX optic towards the RX optic, vertically and horizontally acting as explained above,
until you find the maximum alignment.
N.B.: the fixed buzzer sound has a maximum duration of 3 minutes.To obtain a good alignment it is
necessary to complete a FULL rotation on the horizontal axis of the RECEIVER optic, thereby
performing the SCANNING of the optical signal.This operation is very useful to understand if the
alignment of the optics is taking place directly on the same axis and not through reflection, therefore
deceptive, because the signal value is much lower, despite having reached the hypothetical maximum
alignment signal.
•
The partial or total misalignment condition is signalled by the infrequent flashing of the LEDs and
by the non-continuous whistle of the buzzer.
•
After calibration, tighten the horizontal adjustment screw, and exit the test function by pressing
the TEST button on the TX and RX optics for 3 seconds.
•
Repeat all the operations on each beam of the barrier.