Operating principles and applications
The system is designed for detection in the event of a breach, trespassing and cutting.
In the case of mounting on masonry, the system only detects an attempt at breaching.
In the case of mounting on netting, cut detection occurs when a potential intruder cuts the
netting/mesh and tries to pass through it.
In the case of non-welded netting/mesh mounting, it is necessary to use a panel sensor to have an
efficient level of protection against cutting.
The system works properly only if the fencing is stable and uniform.
Standard applications
-
Light wire mesh panels
: typical mounting in the centre of alternate panels, i.e. one yes, one no.If
vibrations are propagated considerably, it is possible the to mount one every three panels, i.e. one
yes and two no.
-
Rigid wire mesh panel
: typical mounting in the centre of alternate panels, i.e. one yes, one no.If
vibrations are not propagated very much, mount a sensor on each panel.
-
Non-welded meshing:
typical mounting near the anchoring post, mounting of a sensor on each
section for cutting detection.
-
Rigid welded meshing
: typical mounting in the centre of alternate sections, i.e. one yes, one no.If
vibrations are propagated considerably, it is possible to mount one every three panels, i.e. one yes
and two no.
-
Anti-breach wall
: depending on the structure of the wall, typically mount a sensor every 5m.
-
Windows or internal applications
: mount a sensor every 5m depending on the structure.