37
•
When replacing the Outer Housing, be sure the Bright Frame “b” (Figure 3-7) is in
front of the molded support “c” on the inside of the Outer Housing, and that support “c”
does not bind the Bright Frame after assembly.
Note: The Eye Cup is mounted with its thicker vertical edge “d” (Figure 3-8) nearest
the Camera Body.
Figure 3-7. Bright frame reassembly
•
Replace the Front Glass “f” shiny side out, frosted area at the bottom. Replace the
Front Cover “e” with the thicker vertical edge nearest the Camera Body (Figure 3-8).
Figure 3-8. Eye cup, front glass and front cover reassembly
Содержание Miniportrait 455
Страница 7: ...7 Figure 1 1 Model 455 miniportrait camera...
Страница 10: ...10 Figure 1 2 Model 455 camera dimensions...
Страница 25: ...25 Figure 2 11 Electronic flash PC board schematic...
Страница 26: ...26 Figure 2 12 Sonar PC board schematic...
Страница 27: ...27 Camera Wiring Diagram Figure 2 13 Camera Wiring Diagram...
Страница 34: ...34 Figure 3 2 Hand grip disassembly...
Страница 42: ...42 Figure 3 11 Electronic flash unit disassembly...
Страница 45: ...45 Figure 3 13 Removing Shutter Assembly from Camera Body A Main PC Board C X Sync Connections B Removing Leads...
Страница 48: ...48 Figure 3 16 Removing M blade assembly from shutter Figure 3 17 M blade assembly component parts...
Страница 59: ...59 Figure 3 30 Front panel replacement Figure 3 31 Wiring placement...