4. If the STOP ERROR display readings are not within specifications,adjust the Strobe Exposure
Calibration Wheel (Figure 3-6) with a dental pick. Rotate wheel clockwise (CW) to decrease
exposure or counter clockwise (CCW) to increase exposure.
5. Retest the camera. If necessary, repeat this calibration procedure until the Strobe exposure is
correct.