3 - 5
Testing
Ambient Exposure Test
Purpose
The Ambient Exposure Test is used to measure the energy of the film plane during an ambient (visible)
light exposure. The Star Tester light integrating sphere provides a constant scene brightness level of
100 candles/ft
2
.
Setup (Figure 3-3)
1. Open the camera door.
2. Using a solder aid tool, manually trip the camera door switch into its down position.
3. Using a solder aid tool, remove the front cover from the camera.
4. Install the Joshua Test Cover in place of the removed front cover.
5. Set the Joshua Test Cover Strobe/Ambient(STB/AMB) switch to its Ambient (AMB) position.
6. Place the camera with the Joshua Test Cover onto the Joshua Horn Assembly.
7. Remove the 640 Nest Assembly from the Star Tester.
Figure 3-3. Ambient Exposure Test Setup
CAMERA
CAMERA DOOR
SWITCH
JOSHUA TEST
COVER
AMBIENT/STROBE
TRIM WHEELS
JOSHUA HORN
ASSEMBLY
Содержание Joshua Captiva
Страница 6: ...This page intentionally blank...
Страница 7: ...1 1 1 Description...
Страница 15: ...1 9 Figure 1 6 Joshua System Features...
Страница 23: ...1 17 Figure 1 16 Principal Parts of the Joshua Drive System...
Страница 31: ...1 25 Figure 1 22 Joshua Components Covers and Panels...
Страница 32: ...This page intentionally blank...
Страница 33: ...2 1 2 Theory of Operation...
Страница 36: ...2 4 Figure 2 1 Pictorial ChartShowing JoshuaCamera Sequence of Operation...
Страница 57: ...2 25 Figure2 31 Circuit Diagram...
Страница 58: ...This page intentionally blank...
Страница 59: ...3 1 3 Testing and Adjustments...
Страница 72: ...This page intentionally blank...
Страница 73: ...4 1 4 Disassembly and Reassembly...
Страница 108: ...This page intentionally blank...
Страница 109: ...5 1 5 Troubleshooting...
Страница 122: ...5 14 5 14...
Страница 123: ...5 15 Figure 5 7 Joshua Camera Timing Diagram...
Страница 124: ...This page intentionally blank...
Страница 125: ...A 1 Appendix...
Страница 134: ...This page intentionally blank...