35
DMC Repair Manual
Parts Replacement
XSYNC Connector (Figure 2-11)
Removal
1. Remove the rear panel and XSYNC assembly.
2. Using a small flat scredriver, remove the screw securing the XSYNC cable to the XSYNC
assembly.
Note: XSYNC assembly consists of:
•
XSYNC assembly (connector)
•
XSYNC cable and screw
•
Nylon shoulder washer
3. Using the XSYNC nut driver, remove the nut and lug cable asssembly that secures the XSYNC
assembly to the rear panel.
Note: Nut and lug assembly consists of:
•
nut
•
Inner shoulder washer
•
XSYNC lug cable
4. Lift off the XSYNC assembly and nut and lug cable assembly from the rear panel.
Figure 2-11. Replacing XSYNC assembly
Rear Panel
Nut
Screw
XSYNC Cable
Nylon Shoulder
Washer
Inner Shoulder
Washer
XSYNC
Lug Cable
XSYNC
Assembly
Содержание Digital Microscope Camera
Страница 5: ...1 Camera Overview...
Страница 6: ...6 DMC Repair Manual Camera Overview 1 Camera Overview Contents Overview 7 Features 8 Specifications 11...
Страница 13: ...2 Parts Replacement...
Страница 37: ...3 Testing and Adjustment...