12.42
9850045 R01 - 2020-2021 RANGER 1000 Service Manual
© Copyright Polaris Inc.
BATTERY SPECIFIC GRAVITY TEST
A tool such as a Battery Hydrometer (2870836) can be
used to measure electrolyte strength or specific gravity.
As the battery goes through the charge / discharge cycle,
the electrolyte goes from a heavy (more acidic) state at
full charge to a light (more water) state when discharged.
The hydrometer can measure state of charge and
differences between cells in a multi-cell battery.
Readings of 1.270 or greater should be observed in a
fully charged battery. Differences of more than .025
between the lowest and highest cell readings indicate a
need to replace the battery.
STATE OF
CHARGE
LEAD ACID
CONVENTIONAL
/ DRY SHIPPED
AGM
LOW
MAINTENANCE
100% Charged 12.60V
12.70V
75% Charged
12.40V
12.50V
50% Charged
12.10V
12.20V
25% Charged
11.90V
12.0V
0% Charged
less than 11.80V
Less than 11.90V
STATE OF
CHARGE*
LEAD ACID
CONVENTIONAL
/ DRY SHIPPED
AGM
LOW
MAINTENANCE
100% Charged 1.265
1.275
75% Charged
1.210
1.225
50% Charged
1.160
1.175
25% Charged
1.120
1.135
0% Charged
less than 1.100
Less than 1.115
* Measurement at 80° F
NOTICE
Subtract .01 from the specific gravity reading at 40° F
BATTERY CHARGING PROCEDURE
If battery voltage is 12.6 Vdc or less, the battery may
need recharging. When using an automatic charger, refer
to the charger manufacturer’s instructions for recharging.
Recommended Charging Rate: 1 hour @ 6-10 Amps.
Do not exceed 10 amps when charging the battery.
NOTICE
Charge the battery using an automatic charger that will
not exceed 14.6 Vdc. An automatic charger will signal
when charging is complete.
Allow the battery to stand disconnected for at least 1-2
hours after being properly charged. If the voltage drops
below 12.6 volts, charging was ineffective or the battery
needs to be replaced.
DANGER
An overheated battery could explode, causing severe
injury or death. Always watch charging times carefully.
Stop charging if the battery becomes very warm to the
touch. Allow it to cool before resuming charging.
BATTERY PN 4014043 / 4014132-P
STATE OF
CHARGE
VOLTAGE
(DC)
ACTION
CHARG-
E TIME
100%
12.8 or
more
None, check
again in 3
months
None
Required
75% -
100%
12.6 - 12.8
May need
slight charge
3 - 6 hrs
50% - 75%
12.3 - 12.6
Needs
Charge
5 - 11 hrs
25% - 50%
12.0 - 12.3
Needs
Charge
At least
13 hrs
0% - 25%
12.0 or less
Needs
Charge
At least
20 hrs
NOTICE
Follow the charger instructions supplied by the
manufacture regarding the order or connections, switch
positions and when to connect the charger to an outlet.
Содержание RANGER 1000 2020
Страница 4: ...REVISION INDEX REV DATE CHANGES R01 11 06 2020 Initial release...
Страница 6: ......
Страница 8: ......
Страница 88: ...1 80 9850045 R01 2020 2021 RANGER 1000 Service Manual Copyright Polaris Inc NOTES GENERAL INFORMATION...
Страница 280: ...4 34 9850045 R01 2020 2021 RANGER 1000 Service Manual Copyright Polaris Inc NOTES ENGINE ELECTRICAL...
Страница 308: ...5 28 9850045 R01 2020 2021 RANGER 1000 Service Manual Copyright Polaris Inc NOTES FUEL SYSTEM...
Страница 344: ...7 8 9850045 R01 2020 2021 RANGER 1000 Service Manual Copyright Polaris Inc SIDE VIEW TRANSMISSION...
Страница 374: ......
Страница 581: ...12 9850045 R01 2020 2021 RANGER 1000 Service Manual Copyright Polaris Inc 12 27 CHASSIS BODY ELECTRICAL...