Location Requirements

The water heater design has been tested by CSA 

International and complies with ANSI Z21.10.1, Section 

2.35 Flammable Vapors Resistance.  In garage installation 

avoid damage to your water heater by installing a vehicle 

stop as shown in figure below.  Check state and local 

codes for requirements prior to installation.

Important:

  The water heater should be located in 

an area where leakage of the tank or connections will 

not result in damage to the area adjacent to the water 

heater or to lower floors of the structure. 

Due to the 

normal corrosive action of the water, the tank will 

eventually leak after an extended period of time. 

Also any external plumbing leak, including those 

from improper installation, may cause early failure 

of the water tank due to corrosion if not repaired. 

A qualified service technician should be contacted 

for repairs.

  A suitable metal drain pan should be 

installed under the water heater as shown below, to 

help protect the property from damage which may 

occur from condensate formation or leaks in the piping 

connections or tank. The pan must limit the water level 

to a maximum depth of 1-3/4” (4.45 cm) and be at least 

two inches (5 cm) wider than the heater and piped to an 

adequate drain. Locate the water heater near a suitable 

indoor drain. Outside drains are subject to freezing 

temperatures which can obstruct the drain line. The 

piping should be at least 3/4” (1.91 cm) ID and pitched 

for proper drainage. Under no circumstances will the 

manufacturer or seller of this water heater be held liable 

for any water damage which is caused by your failure to 

follow these instructions.

 

The water heater should be located in an area not sub-

ject to freezing temperatures. Water heaters  located in 

unconditioned spaces (i.e., attics,  basements, etc) may 

require insulation of the  water piping and drain piping 

to protect against freezing. The drain and controls must 

be easily accessible for operation and service. Maintain 

proper clearances as specified on the data plate.

 

Figure 1: Garage Installation 

Do not store or use gasoline or other 

flammable vapors and liquids in the vicinity 
of this or any other appliance. Storage of or 
use of gasoline or other flammable vapors 
or liquids in the vicinity of this or any other 
appliance can result in serious injury or death

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

This water heater is not certified for installation in mobile 

homes.

Note:

 In the State of California, the water heater must be 

braced, anchored, or strapped to avoid moving during an 

earthquake. Contact local utilities for code requirements in 

your area or call 1-800-999-9515 and request instructions.

Site Location

 

Select a location near the center of the water piping 

system. The water heater must be installed   indoors 

and in a vertical position on a level surface. DO NOT 

install in bathrooms, bedrooms, or any occupied room 

normally kept closed. 

Note:

 The water heater may be 

installed in a closet with a door off a bedroom or bath-

room providing the units are installed and vented per 

the manufacturer’s instructions.

 

Consider the inlet and exhaust vent system piping  

when selecting the water heater location.  The venting 

system must be able to run from the water heater to 

the termination with a minimal length and number of 

elbows.  Input rates are reduced as vent system length 

increases.  The venting system must comply with the 

requirements  set forth in the venting section of this 

manual.

 

Locate the water heater near the existing gas piping. 

If installing a new gas line, locate the water heater to 

minimize the pipe length and elbows.

Important:

  Air for combustion and ventilation must not 

come from a corrosive atmosphere.  Any failure due to cor-

rosive elements in the atmosphere is excluded from war-

ranty coverage.

Note:

  The water heater must be installed according to all 

local and state codes or in absence of the local and state 

codes with the “National Fuel Gas Code”, ANSI Z223.1 

(NFPA 54)-current edition.  Canadian installations must be 

performed in accordance with CAN/CSA-B149.1-current 

edition. 

1-3/4” (4.45 cm) Max.

(5 cm)

Figure 1A

Содержание PG 34-100-2NV or 2PV

Страница 1: ...hbor s telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agenc...

Страница 2: ...r these conditions we recommend the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance which is connected to the hot water system If hydrogen is p...

Страница 3: ...orized service person The manufacturer and seller of this water heater will not be liable for any damages injuries or deaths caused by failure to comply with the installation and operating instruction...

Страница 4: ...tally vented gas fueled heat ing appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The s...

Страница 5: ...intain proper clearances as specified on the data plate Figure 1 Garage Installation Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance S...

Страница 6: ...tolerance 1 9 cm 0 31 cm tolerance Note The trap should be aligned so that the exhaust pipe is in a vertical position close to the surface of the water heater Figure 2 Minimum Clearance Locations Back...

Страница 7: ...ne into the metal drain pan VENT PIPE SYSTEM Carbon Monoxide Hazard Follow all instructions to locate and install the vent pipe system Instructions can be found in this manual in state or local codes...

Страница 8: ...shell housing by turning clockwise approximately 1 2 30 5 cm and pulling off of the internal clamshell housing see figure 4C Using your fingers or a small flat blade screwdriver remove the filter medi...

Страница 9: ...the specified CSA listed plastic vent pipe All joints in the inlet and outlet piping must be properly cemented Size and cut all piping before cementing 1 Cut the pipe end square and remove all ragged...

Страница 10: ...tain a 36 in 91 cm minimum clearance below a window or door that may be opened C Clearance to permanently closed window D 12 in 30 cm min vertical clearance to ventilated soffit located above the term...

Страница 11: ...Units on Page 12 for correct terminations if installing more than one Polaris gas water heater Alternative Horizontal Termination The combustion air and exhaust terminations may be raised up to 24 inc...

Страница 12: ...ne or anticipated snow levels See figure 9 below Note See Venting Additional Polaris Units below if installing more than one Polaris gas water heater Venting Additional Polaris Units When using two 2...

Страница 13: ...hrough the Roof Termination Notes 1 Support Horizontal Pipe Every Four Feet 1 2 m Support Vertical Pipe Every Six ft 1 8 m 2 Increase The 12 Inch 30 5 cm MinimumAbove Grade To Keep Inlet OpeningAboveA...

Страница 14: ...supply use 1 NPT to the fitting marked HOT OUTLET 2 Always use a suitable grade of joint compound and be certain that all fittings are tightened properly 3 The installation of unions in both the hot...

Страница 15: ...l contaminate the potable water supply Closed System Thermal Expansion As water is heated it expands thermal expansion In a closed system the volume of water will increase As the volume of water incre...

Страница 16: ...the water heater should be ver tical past any mixing valve or supply line to the heating system to remove air bubbles from the system Do not connect the water heater to any system or components previo...

Страница 17: ...ine Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line Must not be capped blocked plugged or contain any valve between the relief...

Страница 18: ...9 for gas piping installation 1 Install a readily accessible manual shut off valve in the gas supply line as recommended by the local utility Know the location of this valve and how to turn off the ga...

Страница 19: ...onally listed recognized fuel gas and carbon monoxide CO detectors are recommended in all applications and should be installed using the manufacturer s instructions and local codes rules or regulation...

Страница 20: ...electrical wiring to the water heater 1 Shut off the power at the electrical service box 2 Loosen the screws securing the access panel to the electrical compartment The electrical wiring diagram model...

Страница 21: ...T L1 NEUTRAL GND PSI PSO PRESSURE SWITCH BLACK WHITE WHITE RED LED YELLOW LED GREEN LED BROWN YELLOW RED THERMOSTAT DIAL ORANGE GAS VALVE BROWN BLUE BLUE WHITE IGNITER RED GREEN YELLOW ORANGE RED 24V...

Страница 22: ...1 8 per foot 10 5 mm per meter Away from corners other vents windows etc Alternate Horizontal Correct relationship outlet to inlet 12 Min 30 5 cm above anticipated snow level 2 exhaust outlet air inle...

Страница 23: ...ich signals the beginning of the ignition sequence see figure 21 and Red Ignition control is signaling the gas valve to open Figure 21 Sequence of Operation When the thermostat calls for heat the blow...

Страница 24: ...e thermostat is adjusted to its lowest temperature setting when it is shipped from the factory Water temperature can be regulated by moving the temperature dial to the preferred setting The preferred...

Страница 25: ...eing shut down during freezing temperatures To drain the tank perform the following steps 1 Turn off the gas supply at the Manual Gas Shut off Valve Turn off the electrical supply to the water heater...

Страница 26: ...Remove the gas valve from the unit keeping the rubber gasket with the gas valve 8 Remove the flange from the gas inlet side of the valve by removing the four 4 attachment screws Figure 25 Replacing t...

Страница 27: ...arity Detection SC SL Soft Lockout Control Automatically resets after 60 minutes SL3 Soft Lockout Hard Lockout Control automatically resets after 60 minutes with a maximum of 3 resets followed by hard...

Страница 28: ...28 SOFTWARE OPERATION SEQUENCE IGNITION CONTROL MODULE SOFTWARE OPERATION SEQUENCE...

Страница 29: ...TE TRAP ASSEMBLY 32 COLD WATER TUBE ASSEMBLY 33 TEMPERATURE AND PRESSURE RELIEF VALVE 34 DRAIN VALVE 35 POTENTIOMETER 36 VENTURI GASKET not pictured 37 BLOWER ISOLATION RELAY TOOLS REQUIRED FOR SERVIC...

Страница 30: ...15 3 4 40 1 2 41 6 3 8 5 1 2 6 5 8 150 PG 34 150 2NV OR 2PV 34 150 2 OR 3 48 1 2 22 15 3 4 40 1 2 41 6 3 8 5 1 2 6 5 8 150 PG 50 130 2NV OR 2PV 50 130 2 OR 3 62 3 8 22 15 3 4 54 1 2 55 6 3 8 5 1 2 6 5...

Страница 31: ...31 NOTES...

Страница 32: ...d To obtain technical warranty or service assistance during or after the installation of this water heater visit our website at http www americanwaterheater com or call toll free 1 800 456 9805 P O Bo...

Отзывы: