INSTALLATION CHECKLIST
Water Heater Location 

Requirements

…

 

Centrally located with the water piping system. Located 
as close to the gas piping and vent pipe system as pos-
sible.

…

  Located indoors and in a vertical position. Protected   

from freezing temperatures.

…

  Proper clearances from combustible surfaces main-

tained and not installed directly on a carpeted floor. 
Sufficient room to service the water heater.

…

  Provisions made to protect the area from water dam-

age. Properly sized metal drain pan installed and piped 
to an adequate drain.

…

  Installation area free of corrosive elements and      

flammable materials.

Condensate Line

…

 

Drain stem is fully inserted in the elbow and glued   

properly.

…

 

Trap aligned so that the exhaust pipe is in a vertical 

position close to the surface of the water heater.

…

 

Line properly sloped to adequate drain or approved    

condensate pump.

…

 

Properly vented.

…

 

Protected from freezing (if required).

Vent Pipe System

…

 

Vent pipe and fittings of approved material. 

…

 

Acceptable size, length, and number of elbows on air 
inlet pipe.

…

 

Acceptable size, length, and number of elbows on 
exhaust outlet pipe.

…

 

Add the air inlet filter per the manufacturer’s instruction.

…

 

Installed in accordance with prevailing provisions of 
Local codes, or in the absence of such, National  Fuel  
Gas Code, NFPA 54, ANSI Z223.1-Current Edition.  
Canadian Installations must be performed in accor-
dance with CAN/CSA-B149.1-Current Edition.

…

 

All 2” horizontal piping sloped down toward the water 
heater at 1/4” per foot (21 mm per meter). 3” piping 
sloped down towards the heater at 1/8” per foot (10.5 
mm per meter). 

…

 

Not obstructed in any way.

Vent Termination

    

       

Horizontal

…

 

Correct relationship - outlet to inlet.

…

 

12” Min. (30.5 cm) above grade/snow level.

…

 

2” exhaust outlet/air inlet pipe sloped down towards 
water heater at 1/4” per foot (21 mm per meter).  3” 
piping sloped down towards the heater at 1/8” per foot 
(10.5 mm per meter). 

…

 

Away from corners, other vents, windows, etc.

 Alternate 

Horizontal

…

 

Correct relationship - outlet to inlet.

…

 

12” Min. (30.5 cm) above anticipated snow level.

…

 

2” exhaust outlet/air inlet pipe sloped down towards 

water heater at 1/4” per foot (21 mm per meter).  3” 

piping sloped down towards the heater at 1/8” per foot 
(10.5 mm per meter). 

…

 

Away from corners, other vents, windows, etc.

       

Vertical

…

 

Inlet - 12” Min. (30.5 cm) above roof/snow level.

…

 

Correct relationship - outlet to inlet.

…

 

Away from corners, other vents, windows, etc.

 

Concentric

…

 

12” Min. (30.5 cm) above grade/snow level.

…

 

2” exhaust outlet/air inlet pipe sloped down towards 
water heater at 1/4” per foot (21 mm per meter).  3” 
piping sloped down towards the heater at 1/8” per foot 
(10.5 mm per meter). 

…

 

Away from corners, other vents, windows, etc.

Water System Piping

…

 

Temperature and pressure relief valve properly 
installed with a discharge line run to an open drain and 
protected from freezing.

…

 

All piping properly installed and free of leaks.

…

 

Heater completely filled with water.

…

 

A properly sized expansion tank must be installed on all 
closed systems.

…

 

A mixing valve must be installed per the manufacturer’s 
instructions.

Gas Supply and Piping

…

 

If using a flexible gas connector, make sure its rating 
tag matches or exceeds the input of the  water heater.

…

 

Adequate pipe size and of approved material.

…

 

Gas supply is the same type as listed on the water    
heater data plate.

…

 

Gas line equipped with full opening shut-off valve,   
union and drip leg.

…

 

Approved pipe joint compound used.

…

 

Chloride-free soap and water solution or other  ap-
proved means used to check all connections and fit-
tings for possible gas leaks.

Electrical Connections

…

 

Unit connected to a dedicated power supply.

…

 

Unit connected to a 120V electrical supply.

…

 

Proper polarity.

…

 

Water heater properly grounded.

…

 

Installed in accordance with prevailing provisions of 
local codes, or in the absence of such, National Fuel  
Gas Code, NFPA 54, ANSI Z223.1-Current Edition.  
Canadian installations must be performed in accor-
dance with CAN/CSA-B149.1-Current Edition.

Содержание PG 34-100-2NV or 2PV

Страница 1: ...hbor s telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agenc...

Страница 2: ...r these conditions we recommend the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance which is connected to the hot water system If hydrogen is p...

Страница 3: ...orized service person The manufacturer and seller of this water heater will not be liable for any damages injuries or deaths caused by failure to comply with the installation and operating instruction...

Страница 4: ...tally vented gas fueled heat ing appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The s...

Страница 5: ...intain proper clearances as specified on the data plate Figure 1 Garage Installation Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance S...

Страница 6: ...tolerance 1 9 cm 0 31 cm tolerance Note The trap should be aligned so that the exhaust pipe is in a vertical position close to the surface of the water heater Figure 2 Minimum Clearance Locations Back...

Страница 7: ...ne into the metal drain pan VENT PIPE SYSTEM Carbon Monoxide Hazard Follow all instructions to locate and install the vent pipe system Instructions can be found in this manual in state or local codes...

Страница 8: ...shell housing by turning clockwise approximately 1 2 30 5 cm and pulling off of the internal clamshell housing see figure 4C Using your fingers or a small flat blade screwdriver remove the filter medi...

Страница 9: ...the specified CSA listed plastic vent pipe All joints in the inlet and outlet piping must be properly cemented Size and cut all piping before cementing 1 Cut the pipe end square and remove all ragged...

Страница 10: ...tain a 36 in 91 cm minimum clearance below a window or door that may be opened C Clearance to permanently closed window D 12 in 30 cm min vertical clearance to ventilated soffit located above the term...

Страница 11: ...Units on Page 12 for correct terminations if installing more than one Polaris gas water heater Alternative Horizontal Termination The combustion air and exhaust terminations may be raised up to 24 inc...

Страница 12: ...ne or anticipated snow levels See figure 9 below Note See Venting Additional Polaris Units below if installing more than one Polaris gas water heater Venting Additional Polaris Units When using two 2...

Страница 13: ...hrough the Roof Termination Notes 1 Support Horizontal Pipe Every Four Feet 1 2 m Support Vertical Pipe Every Six ft 1 8 m 2 Increase The 12 Inch 30 5 cm MinimumAbove Grade To Keep Inlet OpeningAboveA...

Страница 14: ...supply use 1 NPT to the fitting marked HOT OUTLET 2 Always use a suitable grade of joint compound and be certain that all fittings are tightened properly 3 The installation of unions in both the hot...

Страница 15: ...l contaminate the potable water supply Closed System Thermal Expansion As water is heated it expands thermal expansion In a closed system the volume of water will increase As the volume of water incre...

Страница 16: ...the water heater should be ver tical past any mixing valve or supply line to the heating system to remove air bubbles from the system Do not connect the water heater to any system or components previo...

Страница 17: ...ine Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line Must not be capped blocked plugged or contain any valve between the relief...

Страница 18: ...9 for gas piping installation 1 Install a readily accessible manual shut off valve in the gas supply line as recommended by the local utility Know the location of this valve and how to turn off the ga...

Страница 19: ...onally listed recognized fuel gas and carbon monoxide CO detectors are recommended in all applications and should be installed using the manufacturer s instructions and local codes rules or regulation...

Страница 20: ...electrical wiring to the water heater 1 Shut off the power at the electrical service box 2 Loosen the screws securing the access panel to the electrical compartment The electrical wiring diagram model...

Страница 21: ...T L1 NEUTRAL GND PSI PSO PRESSURE SWITCH BLACK WHITE WHITE RED LED YELLOW LED GREEN LED BROWN YELLOW RED THERMOSTAT DIAL ORANGE GAS VALVE BROWN BLUE BLUE WHITE IGNITER RED GREEN YELLOW ORANGE RED 24V...

Страница 22: ...1 8 per foot 10 5 mm per meter Away from corners other vents windows etc Alternate Horizontal Correct relationship outlet to inlet 12 Min 30 5 cm above anticipated snow level 2 exhaust outlet air inle...

Страница 23: ...ich signals the beginning of the ignition sequence see figure 21 and Red Ignition control is signaling the gas valve to open Figure 21 Sequence of Operation When the thermostat calls for heat the blow...

Страница 24: ...e thermostat is adjusted to its lowest temperature setting when it is shipped from the factory Water temperature can be regulated by moving the temperature dial to the preferred setting The preferred...

Страница 25: ...eing shut down during freezing temperatures To drain the tank perform the following steps 1 Turn off the gas supply at the Manual Gas Shut off Valve Turn off the electrical supply to the water heater...

Страница 26: ...Remove the gas valve from the unit keeping the rubber gasket with the gas valve 8 Remove the flange from the gas inlet side of the valve by removing the four 4 attachment screws Figure 25 Replacing t...

Страница 27: ...arity Detection SC SL Soft Lockout Control Automatically resets after 60 minutes SL3 Soft Lockout Hard Lockout Control automatically resets after 60 minutes with a maximum of 3 resets followed by hard...

Страница 28: ...28 SOFTWARE OPERATION SEQUENCE IGNITION CONTROL MODULE SOFTWARE OPERATION SEQUENCE...

Страница 29: ...TE TRAP ASSEMBLY 32 COLD WATER TUBE ASSEMBLY 33 TEMPERATURE AND PRESSURE RELIEF VALVE 34 DRAIN VALVE 35 POTENTIOMETER 36 VENTURI GASKET not pictured 37 BLOWER ISOLATION RELAY TOOLS REQUIRED FOR SERVIC...

Страница 30: ...15 3 4 40 1 2 41 6 3 8 5 1 2 6 5 8 150 PG 34 150 2NV OR 2PV 34 150 2 OR 3 48 1 2 22 15 3 4 40 1 2 41 6 3 8 5 1 2 6 5 8 150 PG 50 130 2NV OR 2PV 50 130 2 OR 3 62 3 8 22 15 3 4 54 1 2 55 6 3 8 5 1 2 6 5...

Страница 31: ...31 NOTES...

Страница 32: ...d To obtain technical warranty or service assistance during or after the installation of this water heater visit our website at http www americanwaterheater com or call toll free 1 800 456 9805 P O Bo...

Отзывы: