background image

-

13

-

Hex bolt

side screws
(may be installed
on either side)

(5b) Install And Ground The Unit To 
The Case Unit Installed Through 
Side Of Case

1. Slide the side of the unit into the case. Push

the unit all of the way into the case until it  stops.

NOTE: 

Either of the case sides may be 

              enable the unit to be slid 

             

2. Attach the case side panel to the main case
3. Ground the unit to the case by installing the

front unit-to-case hex-bolt.

removed 

to

into the case.

Inside
wall

Rigid 
ductwork

Flexible or rigid
ductwork

Air
discharge
outlet

(6)Connect  The  Top  Duct

1. Install the duct onto the air discharge outlet.

Case top
duct adjusting
screws

Top duct

Clamp

2. Secure the top duct to the unit by turning the four

case top duct adjusting screws until they are tight.
Use a field supplied clamp to lock the top duct to
the case.

(7)Final Check

Review this Checklist before restoring power.

Correct line voltage?

Single circuit only?

Ductwork connected?

Case and unit level?

Wall plenum caulked? Level? Flashing?

Drain connected?

Unit wired correctly?

Hydronic plumbing connections (if applicable)

Hydronic wiring connections (if applicable)

(8)Connect Power

1. If all the above items are correct, turn

the power on at the main service panel.

2. Turn the unit power switch, on the front

of the unit.

Содержание VTAC

Страница 1: ...INSTALLATION OPERATION SERVICE MANUAL VTAC VTACDC...

Страница 2: ...ain refrigerants which under federal law must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do...

Страница 3: ...elease for one time within 5 seconds Turn OFF unit connect R terminal to LS terminal then release for two times within 5 seconds Force shut down connect R terminal to LS terminal for over 5 seconds No...

Страница 4: ...ng heating airflow and efficiency of the unit Replacement filters should be purchased from your local retailer where air conditioner and furnace accessories are sold Filter size required is 20 x 20 x1...

Страница 5: ...WARNING RISK OF ELECTRIC SHOCK All electrical connections and wiring MUST be installed by a qualified electrician Follow the National Electrical Code N E C a n d o r l o c a l c o d e s a n d ordinanc...

Страница 6: ...unit is properly wired measure the unit supply voltage Voltage must fall within the voltage utilization range LCDI Cords Underwriters Laboratories and the National Electric Code NEC now require power...

Страница 7: ...ase Panel Required Accessories Check the Essential Elements label on the unit Architectural Louver Cutout Dimensions 20 W x 32 1 4 H Wall Plenum 6 D x 19 3 4 W x 32 H 8 D x 19 3 4 W x 32 H 12 D x 19 3...

Страница 8: ...xible or rigid duct Air discharge outlet Unit Wall plenum Wall plenum divider Drain fittings 3 4 Filter bracket Secure platform to the floor 8 min for drain access Platform 23 1 4 x 23 1 4 square Min...

Страница 9: ...nector Primary Drain Centerline of cutout is approximately 5 1 4 from left case wall and 8 1 2 from back case wall Secondary Drain centerline of cutout is approximately 6 1 2 from left case wall and 5...

Страница 10: ...nstallation requirements Follow the Installation Instructions provided with the return air grille accessory for installation details All these options need field supplied accessories NOTE Use only one...

Страница 11: ...H 8 D x 19 3 4 W x 32 H 12 D x 19 3 4 W x 32 H 15 D x 19 3 4 W x 32 H Case Left side of platform 23 1 4 min 8 min for drain access NOTE Specific cutout size for drain connections needs to be determin...

Страница 12: ...the case The total flow rate CFM and external static pressure ESP available can be estimated from the chart below The collar on top of the case accepts standard 10 duct Pull all duct tight Extra duct...

Страница 13: ...g Secondary 3 4 drain option If not used seal with a MNPTplug Primary female drain fitting 3 4 Bolt case to platform External drain OR Internal Drain s NOTE Piping is not supplied with the unit Obtain...

Страница 14: ...nect The Top Duct 1 Install the duct onto the air discharge outlet Case top duct adjusting screws Top duct Clamp 2 Secure the top duct to the unit by turning the four case top duct adjusting screws un...

Страница 15: ...he fan will run continuously whenever power is applied in this mode In the AUTO position the fan will cycle on and off with the compressor or electric heater Starting delay You may notice a few minute...

Страница 16: ...rk applications Switch Description Function Factray Setting 1 Anti cold air ON Enable OFF Disable ON 2 Heat pump ON Enable OFF Disable ON 3 Electric heater ON Enable OFF Disable ON 4 Heat Pump Prior O...

Страница 17: ...ing protection defrosting E9 Refrigerant high pressure protection Solution Check sensor connection Replace it if broken Check sensor connection Replace it if broken Check sensor connection Replace it...

Страница 18: ...m right button on keypad The unit may be in a diagnostic condition Check checking Control section to determine if unit has had a failure The unit may be set for C instead of F see the keypad configura...

Страница 19: ...160421_V 01...

Отзывы: