background image

RO

42

BG:

Опростена декларация за съответствие на ЕС

SC ONLINESHOP SRL декларира, че PNH SafeHouse HS550 алармена система спазва директивата EMC 

2014/30/EU и RED 2014/53/UE. Пълният текст на ЕС декларацията за съответствие е достъпен на следния 

интернет адрес:

https://www.mypni.eu/products/6472/download/certifications

EN:

EU Simplified Declaration of Conformity

SC ONLINESHOP SRL declares that 

PNI SafeHouse HS550 alarm system

 complies with the Directive EMC 

2014/30/EU and RED 2014/53/UE. The full text of the EU declaration of conformity is available at the following 

Internet address:

https://www.mypni.eu/products/6472/download/certifications

DE:

Vereinfachte EU- Konformitätserklärung

SC ONLINESHOP SRL erklärt, dass das 

PNI SafeHouse HS550 Alarmsystem

 der Richtlinie EMC 2014/30/EU 

entspricht und RED 2014/53 / EU-Richtlinie. Sie finden den ganzen Text der EU-Konformitätserklärung an der 

folgenden Internetadresse:

https://www.mypni.eu/products/6472/download/certifications

ES:

Declaración UE de conformidad simplificada

SC ONLINESHOP SRL declara que el 

Sistema de alarma PNI SafeHouse HS550

 cumple con la Directiva EMC 

2014/30/EU y la Directiva RED 2014/53/EU. El texto completo de la declaración de conformidad de la UE está 

disponible en la siguiente dirección de Internet:

https://www.mypni.eu/products/6472/download/certifications

FR

Déclaration de conformité simplifiée de l’UE

SC ONLINESHOP SRL déclare que 

Système d’alarme PNI SafeHouse HS550

 est conforme à la directive EMC 

2014/30/EU et RED 2014/53/UE. Le texte complet de la déclaration de conformité UE est disponible à l’adresse 

Internet suivante:

https://www.mypni.eu/products/6472/download/certifications

HU:

Egyszerűsített EU Megfelelési

 

Közlemény

SC ONLINESHOP SRL kijelenti azt, hogy a 

PNI SafeHouse HS550 riasztórendszer

 megfelel

 

az EMC 2014/30/

EU és RED 2014/53/UE irányelvnek. Az EU-megfelelőségi nyilatkozat teljes szövege a következő internetes címen 

érhető el:

https://www.mypni.eu/products/6472/download/certifications

IT:

Dichiarazione UE di conformità semplificata

SC ONLINESHOP SRL dichiara che il 

Sistema di allarme PNI SafeHouse HS550

 è conforme alla direttiva 

EMC 2014/30/UE e alla direttiva RED 2014/53/UE. Il testo completo della dichiarazione di conformità europea è 

disponibile al seguente indirizzo Internet:

https://www.mypni.eu/products/6472/download/certifications

PL:

Uproszczona deklaracja zgodności UE

SC ONLINESHOP SRL oświadcza, że 

System alarmowy PNI SafeHouse HS550

 jest zgodny z dyrektywą EMC 

2014/30/EU i RED 2014/53/UE. Pełny tekst deklaracji zgodności UE dostępny jest pod następującym adresem 

internetowym:

https://www.mypni.eu/products/6472/download/certifications

RO:

Declaratie UE de conformitate simplificata

SC ONLINESHOP SRL declara ca 

Sistemul de alarma PNI SafeHouse HS550

 este in conformitate cu Directiva 

EMC 2014/30/EU si Directiva RED 2014/53/UE. Textul integral al declaratiei UE de conformitate este disponibil la 

urmatoarea adresa de internet:

https://www.mypni.eu/products/6472/download/certifications

Содержание SafeHouse HS550

Страница 1: ...Sistem de alarma fara fir PNI SafeHouse HS550 Wifi GSM 3G PNI SafeHouse HS550 WIRELESS 3G alarm system Manual de utilizare User manual RO Manual de utilizare 2 EN User manual 22...

Страница 2: ...entire system Both modes provide an entry delay time that allows you to reenter the premises without setting off an alarm Zones Your system s sensing devices have been assigned to various zones For e...

Страница 3: ...o arm perimeter portion programmed for Stay Arm Active of burglary system only Interior protection is not armed which allows movement within premises without causing alarm 5 Disarm Button Press to dis...

Страница 4: ...switch 2 3 Hardwired Zone Connections Zone 1 Zone 2 and Zone 3 are the EOLR supervised zones that supports both open circuit and closed circuit devices and has a response time of 300msec Maximum zone...

Страница 5: ...zone 2 4 Home Screen 2 5 Home Screen description GSM GSM Status SIM No SIM card present or SIM card faulty GPRS Connected to server GSM RSSI level signal strength Signal strength is displayed by a se...

Страница 6: ...backup battery power is low Clock 08 45 Real time Clock Arm Disarm Status Area Date time and week Arm Disarm Status System is Armed Away System is Armed Stay System is Disarmed System Status Display A...

Страница 7: ...ion Description Factory Defaults Main Menu Settings Delay Exit Delay 0 65535 Used to set Exit Delay 0 65535 unit second 40 seconds Entry Delay 0 65535 Used to set Entry Delay 0 65535 unit second 30 se...

Страница 8: ...le Exit Alarm Warning 4 Enable Password System Change System Code 4 digits 5 6666 User Change User Code 6 4 digits 1234 Language English Language Selection 7 English Deutsch Espa ol Polski Italiano Fr...

Страница 9: ...g Alarm Log Used to view system alarm events Arm Log Used to view system arm disarm events Parts Remote Pairing Delete or Delete All the wireless keys Detector Pairing Edit Delete Delete All the wirel...

Страница 10: ...sten to the recorded message Delete Used to delete the recorded message Duration Used to set Record Duration unit second 1 20 is available 20 seconds Timer Arm Timer Used to set a daily time to arm au...

Страница 11: ...n on Home Sreen 4 Door Window Open Warning If enabled the system will generate a Exit Alarm Warning notification when you leaving a door or window open after the exit delay expires 5 System Password u...

Страница 12: ...he Internet AC Power Connections Connect the Power Supply to the DC 5V micro USB port and push the backup battery switch to ON 3 2 Setting Phone Numbers Up to 5 User Phone Numbers used to receive the...

Страница 13: ...e Mode Type You must assign a Zone Type to each zone sensor which defines the way in which the system responds to faults in that zone Stay Arm Active usually assigned to sensors or contacts on entry a...

Страница 14: ...displayed The system will display Device code has been learnt if serial number of tag have been learned RFID Tag Delete Select Main Menu Parts RFID Delete Use the buttons to scroll to the serial numb...

Страница 15: ...via Mobile APP 3 9 Message Recording Message Recording and Playback Your system can Record Playback Delete a brief message up to 20 seconds that can be played back later The message will be played to...

Страница 16: ...S editing the setting text message as below then send it to the SIM number installed in the alarm system panel Your mobile will received an acknowledgement SMS if setting ok System Password Command1 P...

Страница 17: ...ator Access Point Name This is also used for service remote connection For example To set the APN as internet then the remote SMS is 6666 92 internet 5 2 The alarm SMS notification prefix The panel ca...

Страница 18: ...ER reserved 5 4 2 Query the second page of system settings Format is 6666 51 and the panel echoes as follow PHONE set 1 The 1st Phone Number Voice Dialling and SMS switches 2 The 2nd Phone Number Voic...

Страница 19: ...ome To arm the system in stay mode you can operate as below By Wireless Key Press key By Panel Press button twice when home screen is displayed By RFID tag Put the RFID tag close to the RFID area when...

Страница 20: ...s in wireless sensors and displays a Sensor Low Battery message on the home screen means that battery replacement in the indicated sensor s is due within 7 days AC Power Normal Tamper when a cover tam...

Страница 21: ...VAC to 5VDC 1A output Backup battery 3 7V 500mAh Rechargeable Lithium Polymer Battery Consumption 150mA normal Siren Output 300mA Radio Frequency 433 RF code eV1527 GSM 850 900 1800 1900MHz Wi Fi IEEE...

Страница 22: ...0 EU et RED 2014 53 UE Le texte complet de la d claration de conformit UE est disponible l adresse Internet suivante https www mypni eu products 6472 download certifications HU Egyszer s tett EU Megfe...