1
7
The valve offers a safe solution stopping the gas in an emergency
. It can be
connected to a gas sensor for gas leak detection, a fire alarm circuit or other
variants of gas sensors (such as wireless) for gas supply interruption
(manually or automatically) in emergency. The valve features a locking
system automatically detected when input voltages of 9-12 V. After closing,
opening it is done manually by lifting vertically the red button. This function
will ensure safety when there is a defect of the gas.
ELECTROMAGNETISM VALVE - INSTRUCTIONS
Detected gas type: natural gas
Locking mode: current pulse or
manual
Material:
Brass
alloy
Power voltage
: DC 9 ~ 12 V
(Impuls
e
)
Sealing material: rubber NBR
Capacitor discharge: 1000µF
Operating temperature: -10ºC
+50 ºC
Closing time: < 1 sec
.
P max: 100 kPa
Cable length: 0.4 m
Con
ection
: G3/4”
FI
Manual activation
Technical details
Protective cover
Reset button
Operating element
Cable
Brass element