1. Please confirm the induced gas is heavier than air or lighter than air. The
gas is heavier than air: LPG etc. The gas is lighter than air: natural gas,
marsh gas and etc.
2. Choosing the suitable position to install the detector according to the gas
specific gravity. Detecting the gas heavier than air: Installation height from
floor: 0.3-1.0m, Semi-diameter to gas source: <1.5m; Detecting the gas
lighter than air: Installation height from ceiling: 0.3-1.0m, Semi-diameter to
gas source: <1.5m
3. Fix the screw into the wall firmly, then hang the detector.
4. Avoid installing the detector close to the following sources of interference:
direct air flow from vents, fans, doors, windows, sources of steam, oil vapor,
etc.
5. All wires installation must accord with the national and local effective laws
and criteria. The wires must have the suitable size and colorful marks for
avoiding connecting error. And unsuitable connection of wires will result in
the alarm error while gas leaking happened.