5.1
Output Enable (JP1)
This jumper determines when the PMDX-132 outputs are enabled. This controls all of the outputs: step
and direction (i.e. data bus) and control signals. Figure 10 on page 20 shows the location of this jumper.
Setting
Label
Description
1 to 2
not
Estop
Outputs will be enabled whenever an emergency stop or fault condition does not
exist. The “charge pump” is ignored.
2 to 3
CP-OK
Outputs will be enable when “charge pump” is in the OK condition
AND
no
emergency stop or fault condition exists.
Table 14 – “Output Enable” Jumper Settings (JP1)
5.2
Pin 17 Mode (JP2)
This jumper selects which signal is presented on the “pin 17” terminal on connector J9. Figure 10 on page
20 shows the location of this jumper.