TROUBLESHOOTING
If the system does not function (correctly), consult
the checklist below to see if you can remedy the
error yourself. Should this not be possible, contact
your supplier.
WARNING
If applicable, put the Panel in the Service Mode
before you do the activities as stated below; refer to
Symptom
Problem
Possible
cause
Solution
Panel
Yellow
WARNING
LED is on
(with or
without
buzzer)
Refer to HMI
Refer to HMI;
for more info,
refer to the
online user
manual
Refer to HMI
Red ALARM
LED is on +
buzzer
Fan stops
Filter cleaning
stops
HMI
HMI screen is
locked
No control on
HMI possible
Panel is in
service mode
Put the rotary
switch on the Panel
Black screen
HMI does not
function
Loose
connection
Tighten the HMI
cable to the CAN
connector (refer to
Loose or
incorrectly
connected cable
Connect the HMI
cable to the CAN
HMI connector
No
installation
wizard at
start up
Configuration
of the system
not possible
System
configured in
an earlier stage
Direct to screen
5.8
to restart the
wizard manually
If necessary: reset
PIN (refer to online
user manual)
System does
not start
(white LED is
off)
System does
not function
No mains
voltage
Connect the mains
voltage
Main switch is
off
Turn the main
switch to on (refer
White LED
remains off
No indication
LED is defective Replace the LED
Filter and/or
fan pressure
value = 0
when system
is on
No pressure
indication
Loose
pneumatic
hose(s)
Connect the
hose(s)
Filter and/or
fan pressure
value ≠ 0
when system
is off
Wrong
pressure
indication
Wrong pressure
setting
Do a zero point
calibration of the
internal sensors
(refer to screen
1.2)
Fillter
pressure
value is
negative or
illogical
Wrong
pressure
indication
One pneumatic
hose is loose
Connect the hose
Inverted
connection of
the pneumatic
hoses (+ vs. –)
Correct the
connection (refer to
par. 4.5.1)
Wrong type of
external
pressure sensor
configured
(PT-1000 vs.
PT-2500)
Set the correct type
of pressure sensor
(refer to screen
1.2)
Symptom
Problem
Possible
cause
Solution
Malfunction of
frequency
inverter
Fan pressure
value is
negative
Wrong
connection of
the pneumatic
hose (+ vs. –)
Correct the
connection (refer to
par. 4.5.4)
USB stick is
not
recognized
Firmware
update not
possible
USB-stick does
not comply with
USB 2.0
standard (too
slow)
Use a USB 2.0 or
USB 3.0 stick
Filter system
Filter cleaning
sequence is
incorrect or
illogical
No optimum
cleaning
performance
Addressing
sequence is not
correct
Correct the setting
of the DIP
switches; refer to
9
SPARE PARTS
The following spare parts are available for the
product.
9.1
ControlPro/Panel
Refer to exploded view Fig. VI on page 20.
Article no.
Description
0000103139
Switch mode power supply 24V DC 2.5A
0000103141
Rotary switch 0-1
0000113558
Indicator light yellow 24V
0000113559
PCB main board ControlPro
0040900180
Main switch 25A
0324000300
Indicator light white 24V
0324000310
Indicator light green 24V
0324000320
Indicator light red 24V
0328050300
Push button green
0328050320
Push button black
0360000060
Buzzer
9.2
ControlPro/HMI
Refer to exploded view Fig. VII on page 20.
Article no.
Description
0000112777
ControlPro/HMI (complete)
0000113560
Dust cap for ControlPro/HMI
9.3
Control/SlaveBoard
Refer to exploded view Fig. VIII on page 20.
Article no.
Description
0000113561
PCB slave board
10
ELECTRICAL DIAGRAM
Refer to the separately supplied electrical diagram.
11
DISPOSAL
After life of the product, dispose it of in accordance
with federal, state or local regulations.