0000112606/010720/A ControlPro
10
- Due to the cable length, you can only make
horizontal and vertical connections. It is
not
possible to make diagonal connections.
- Refer to Fig. IV on page 19 for an example of
the correct connection sequence.
- In case of an installation with one or more
MDB-BM/2 filter modules, you have
one shorter
cable.
- For the position of the CAN IN and CAN OUT
connectors, refer to Fig. III on page 19.
• Remove the lids of all SlaveBoards.
• Remove the cover caps
24
from the sides.
• If necessary, change the position of the blind plug(s).
• Install 2 tube clamps per cable in the screw holes (A) of
each filter module
25
. Fasten them with a screw.
To install the conduit – including cable – between two
SlaveBoard boxes:
• Remove the nuts of the conduit connectors.
• Put the cable ends through the openings of the SlaveBoard
boxes that you want to connect.
• Put the nuts over the cable ends and fasten them to the
conduit connectors (C).
• Click the conduit in the tube clamps.
• Connect a cable to the CAN OUT
connector of the first filter
module.
• Connect the other end of the cable to the CAN IN connector
of the next filter module.
• Continue the same way to connect all SlaveBoards.
• Put the termination plug
26
(A) on the CAN OUT connector of
the last filter module.
• Put a screw plug in the opening of the last SlaveBoard box
and tighten it with the nut M20
27
.
Cable #3
FIRST filter module
LAST filter module
FIRST
LAST
B
A
C
Fig. 4.16 SlaveBoard
SlaveBoard
Address SlaveBoards
To arrange the compressed air valves of the entire filter
system to pulse in the most effective sequence, you must
configure the DIP switches of each individual filter module.
24. 2 per SlaveBoard
25.
1 tube clamp in case of a filter module MDB-BM/2
26. Supplied with Panel
SlaveBoard cable (#2)
27. Both supplied with Panel
SlaveBoard cable (#1)
The DIP switch module
28
contains 6 DIP switches. Position 5+6
are pre-configured in the factory.
• Make sure that DIP switches position 5+6 are correctly set.
MDB-BM/2
MDB-BM/4
1
2
3
4
Addressing
sequence:
MDB-BM/2 +
MDB-BM/4 +
Configuration of filter module :
Address configuration:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0000112547/A
pos. 5+6
1
2
3
4
Addressing
sequence:
MDB-BM/2 +
MDB-BM/4 +
Configuration of filter module :
Address configuration:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0000112547/A
pos. 5+6
Fig. 4.17 DIP switches position 5+6
• Set the DIP switches 1 to 4 as indicated. It shows the
address configurations of max. 16 filter modules
(=MDB-64).
ATTENTION
Make sure that you address the filter modules in the
correct sequence:
-
start with the upper left filter module (1)
- address from left to right
- subsequently from top to bottom
Addressing sequence
Address configuration pos. 1-4
1
2
3
4
Addressing
sequence:
MDB-BM/2 +
MDB-BM/4 +
Configuration of filter module :
Address configuration:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0000112547/A
1
2
3
4
Addressing
sequence:
MDB-BM/2 +
MDB-BM/4 +
Configuration of filter module :
Address configuration:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0000112547/A
Fig. 4.18 Setting of DIP switches pos. 1 to 4
• Close all lids.
If there is a technical problem with a certain filter module, the
HMI shows the specific number. The outside of the lid contains
a sticker that helps you to identify each separate filter module.
•
Use a black marker to number the filter modules. Make
sure that the sequence corresponds with the setting of the
DIP switches.
Fig. 4.19
Numbering of the filter modules
28. The red module on the PC board