0507061410 DraftMax Eco
EN - 5
The product has been designed to function without problems for
extended periods with minimum maintenance. In order to
guarantee optimal performance level, regular maintenance and
cleaning activities are required which are described in this
chapter. If you observe the necessary caution and carry out the
maintenance at regular intervals, any problems occuring will be
detected and corrected before they lead to a total breakdown.
The indicated maintenance intervals can vary depending on the
specific working and ambient conditions. Therefore it is
recommended to thoroughly inspect the complete product once
every year in addition to the indicated periodic maintenance. For
this purpose contact your supplier.
6.1
Periodic maintenance
The maintenance activities in the table below are strictly
reserved for well trained and authorised service engineers.
1)Connected extraction/filtration facility should be switched on during
cleaning.
If the downdraft table does not function (correctly), consult the
checklist below to see if you can remedy the error yourself.
Should this not be possible, contact your supplier.
Contact your supplier.
After life of the product, dispose it of in accordance with state or
local regulations.
CE declaration not applicable.
6
MAINTENANCE
WARNING
Overdue maintenance can cause fire.
Text printed in italics refers to options and accessories.
ATTENTION!
Always
wear a respirator and gloves during
maintenance.
Clean spark arresters, dust collection tray and optional
dust container(s) preferably using an industrial
vacuum cleaner that meets dust class H according to
EN 60335-2-69.
Component
Action
Frequency
Every 2
weeks
Dust collection
tray
Clean dust collection tray. Dust
collection tray can be emptied:
- using an industrial vacuum cleaner
(preferred way)
- sweeping the dust into the optional
dust container(s)1
- using a dustpan and brush
1
X
Spark arresters
Clean spark arresters using an
industrial vacuum cleaner. Replace if
necessary (refer to section 5.2).
X
Dust
container(s)
Empty the dust container(s).
X
7
TROUBLESHOOTING
Text printed in italics refers to options and accessories.
Symptom
Problem
Possible cause Solution
Poor
extraction
capacity.
Downdraft
table does not
function
properly.
Spark arresters
polluted.
Clean or replace
spark arresters.
Working light
not working
No light.
Cable is not
connected.
Connect cable.
Fluorescent light
is defective.
Replace fluorescent
light.
8
SPARE PARTS
9
DISPOSAL