"Information"  menu  allows  to  preview 
temperatures  being  measured  and  to 
recognize which equipment is currently ON. 

 

Upon 

connection 

of 

mixers' 

extension 

module, 

information 

windows  of  additional  mixers  are 
displayed. 
 

8.23

 

Manual control 

Regulator offers possibility to manual start of 
working equipment such as pump, feeder 
motor or fan.  
This  feature  enables  checking  whether  the 
given  equipment  is  fault-free  and  properly 
connected. Access to manual control menu is 
possible  only  in  STOP  mode,  i.e.  when  the 
boiler is OFF. 

 

Fig.  9  Manual  control  window;  OFF  –  equipment  is 
switched OFF, ON – equipment is switched ON. 

 

 

Note:  Long-term  operation  of  the 
fan,  the  feeder  or  other  working 
equipment  may  lead  to  occurrence 

of hazardous conditions. 

8.24

 

Operation in accordance with the 

schedule 

The  boiler  may  be  set  to  start  in  selected 
time intervals. Time intervals are set in: 

Menu  >  Operation  in  accordance  with 
the schedule 

 
Note: 

the 

option 

of 

Operation 

in 

accordance with the schedule 

may be not 

available  if  the  boiler  manufacturer  did  not 
include this function in the given boiler. 
 

8.25

 

   Favourite menu 

In  the  bottom  screen  bar  there  is  a  key: 

.  Upon  activation  of  this  key,  a 

quick  selection  menu  appears.  To  add  new 
item  to  this  menu  -  hold  respective  icon 
pressed in pie menu for a while. 
To  remove  selected  item  from  favourite 
menu - hold corresponding icon pressed and 
confirm REMOVE. 
 
 
 
 
 
 
 

Manual control 

Fan 

Feeder 

Boiler pump 

Lighter 

HUW pump 

Содержание ecoMAX810P3-L TOUCH

Страница 1: ...ich are available in modules respectively A B C SERVICE AND ASSEMBLY MANUAL ISSUE v1 1 APPLICABLE TO SOFTWARE MODULE A MODULE B PANEL v04 30 v04 30 v04 Boiler regulator ecoMAX810P3 L TOUCH FOR PELLET...

Страница 2: ......

Страница 3: ...other changes in the boiler fittings which can influence the burning process The fittings should correspond to the components installed by the manufacturer p 26 It is recommended to operate boiler wit...

Страница 4: ...3 9 CONNECTION OF TEMPERATURE SENSORS 30 13 10 CONNECTION OF WEATHER SENSOR 30 13 11 TESTING OF TEMPERATURE SENSORS 30 13 12 CONNECTION OF MIXERS ROOM THERMOSTAT 31 13 13 CONNECTION OF RESERVE BOILER...

Страница 5: ...CONTAINER LOADING 42 22 9 FAN DAMAGE 42 23 OTHERS 42 23 1 POWER FAILTURE 42 23 2 ANTI FREEZING PROTECTION 42 23 3 PROTECTION OF PUMPS AGAINST CLOGGING 42 24 REPLACEMENT OF PARTS AND COMPONENTS 42 24...

Страница 6: ...gulator a boiler manufacturer should check if the regulator s mating with the given boiler type is proper and whether it can cause danger The regulator is not an intrinsically safe device which means...

Страница 7: ...ters It can be used in a household and similar facilities as well as in light industrialized facilities 3 Information about documentation The regulator manual is a supplement for the boiler manual In...

Страница 8: ...8 REGULATOR INSTRUCTION MANUAL ecoMAX810P3 L TOUCH...

Страница 9: ...ction Automatic detection SUMMER mode SUMMER mode act temperature SUMMER mode deact temperature Night time decrease HUW HUW pump mode OFF Priority No priority Summer Mixer 1 4 settings Preset mixer te...

Страница 10: ...ing increase of preset boiler temperature by mixer circuit increase of preset temperature for buffer loading Both left and right windows may display different information By touching the screen you ma...

Страница 11: ...led regulator attempts to clean the furnace and fire it up poker is activated to operate over Poker cycle time fuel is supplied over Feeding time fan turns on with the power set in the parameter of Bl...

Страница 12: ...by the boiler manufacturer in accordance with sec 26 1 In case this mode has not been activated when attempting to change the mode a prompt FUNCTION NOT AVALAIBLE appears Change of settings of Individ...

Страница 13: ...the case of Standard control mode upon reaching preset boiler temperature during Individual Fuzzy Logic control upon exceeding the preset boiler temperature by 5 C In the Individual Fuzzy Logic mode...

Страница 14: ...boiler is put out and awaits signal to resume heating A signal to start heating can be decrease in preset boiler temperature below the preset temperature minus the value of boiler hysteresis Boiler hy...

Страница 15: ...nnecting room thermostat it is necessary to set a value of decrease in preset mixer temperature by thermostat parameters Mixer room therm e g at 5 C This value should be selected by trial and error Th...

Страница 16: ...coefficient too high may cause cyclical fluctuations of the room temperature 8 17 Weather controlled operation Depending on the temperature measured outside the building both preset boiler temperature...

Страница 17: ...ervals set the parameter Night time decrease for the given heating circuit at ON Night time decrease may be set separately for working days Saturdays and Sundays Fig 6 Time interwal setting window Sel...

Страница 18: ...onding to 100 level of the fuel tank and set 100 level as described above Description of operation The regulator calculates the fuel level basing on the current fuel consumption Default settings do no...

Страница 19: ...ON Note Long term operation of the fan the feeder or other working equipment may lead to occurrence of hazardous conditions 8 24 Operation in accordance with the schedule The boiler may be set to sta...

Страница 20: ...REGULATOR INSTALLATION AND SERVICE SETTINGS MANUAL ecoMAX810P3 L TOUCH...

Страница 21: ...Blow in output 100 Feeder operation 100 Feeder interval 50 Blow in output 50 Feeder operation 50 Feeder interwal 30 Blow in output 30 Feeder operation 30 Feeder interval Burning off Buring off time Ai...

Страница 22: ...W pump 12 start once the boiler temperature has exceeded CH pump activation temperature usually 40 C In case the water which flows to the boiler is cold thermostatic valve 7 closes It causes the flow...

Страница 23: ...ting floor heating 55 C 26 room thermostat of mixer 3 27 mixer temperature sensor 3 28 mixer servo 4 29 mixer pump 4 30 room thermostat of mixer 4 31 mixer temperature sensor 4 32 extension mixer modu...

Страница 24: ...15 65 C During transport the device cannot be exposed to vibrations greater than those typical of normal road transport 13 MOUNTING REQUIREMENTS Basic version of the equipment is composed of three mod...

Страница 25: ...ided Assembly shall assure IP rating appropriate to the environment conditions in which the regulator will operate Moreover access of the user to live parts under hazardous voltage e g terminals shall...

Страница 26: ...herefore the terminals of working module have to be isolated and access to this section of the housing must be prevented To get access to the terminals disconnect power supply make sure terminals and...

Страница 27: ...Wire ending protection a correct b incorrect Connect power supply wires to terminals indicated with an arrow 13 8 Protective connection Connect protective wire of power supply cable to ground strip li...

Страница 28: ...ring diagram of sensors for A and B module For safety reasons the regulator shall be equipped with the set of pins inserted to 230 VAC power supply connectors even in case no load is connected to the...

Страница 29: ...ature sensor type CT4 T room thermostat use only two wires for connection do not make connection using four wires risk of regulator damage A ecoMAX810P3 L TOUCH main regulator P3 power supply cable 23...

Страница 30: ...allow sensor wires to contact hot parts of the boiler and heating system Wires of temperature sensors are heat resistant to the temperature not exceeding 100 C 13 10 Connection of weather sensor Regul...

Страница 31: ...ttings see sec 8 16 13 13 Connection of reserve boiler Regulator may control reserve oil or gas fired boiler In such case manual start and stop of reserve boiler is not necessary Reserve boiler starts...

Страница 32: ...to use reserve boiler In OFF mode control of CH system is disabled mixer HUW and boiler pumps and mixer control are inactive Fig 22 Hydraulic diagram with reserve boiler connection of open and close...

Страница 33: ...should signal few selected alarms e g AL2 and AL4 alarms sum up the values indicated in the table for individual alarms i e 2 8 10 and set this parameter at this value If any of the alarms AL1 AL2 AL3...

Страница 34: ...boiler Acc recent regulations use of safety temperature limiters is mandatory 13 18 Connection of room control panel Regulator may be equipped with ecoSTER TOUCH room control panel which may perform f...

Страница 35: ...time of fuel feeding and fan operation in SUPERVISION mode see sec 8 8 Setting this parameter at 0 causes that only fan will be ON in SUPERVISION mode Value of this parameter may not be too high beca...

Страница 36: ...e above the maximum value configurable in this parameter Set this value acc recommendation of boiler manufacturer 14 10 Min blow in output During first start up of the boiler set the minimum blowing p...

Страница 37: ...slower the boiler temperature approaches the preset value Setting higher value gives more probability that oscillations of preset boiler temperature will not occur Too low value may cause instability...

Страница 38: ...an preset boiler temperature 15 7 Heat exchanger When the parameter Heat exchanger is set at YES CH pump does not stop when HUW priority is set nor in HUW SUMMER mode This parameter is intended only f...

Страница 39: ...ed other values 16 5 Proportional range Note Change of this parameter is not recommended It is the value of mixer stroke The higher the value is the faster the mixer circuit achieves the preset value...

Страница 40: ...ambda sensor Note do not set too high values because it may adversely affect regulation process Parameters A B C Lambda affect the adjustment speed of oxygen value present in exhaust to the preset oxy...

Страница 41: ...ps the feeder and does not activate it again even though the feeder temperature remains high Alarm may be reset only upon drop of feeder temperature To reset the alarm press encoder knob or switch off...

Страница 42: ...tion stops Note the function of fan rotation detection has to be enabled by the boiler manufacturer 23 OTHERS 23 1 Power failture In case of power failure the regulator returns to the operation mode i...

Страница 43: ...y cause incorrect operation of the regulator 24 3 Replacement of working module The requirements are the same as for the replacement of control panel see sec 24 2 24 4 Software up grade To up grade th...

Страница 44: ...ion unlock it by removing the lid and pushing the button in accordance with the documentation provided by the boiler manufacturer check the fan and replace it if necessary Fuel feeder inoperative fail...

Страница 45: ...VIDUAL FUZZY LOGIC PROGRAM IS SELECTED INDIVIDUALLY TO THE GIVEN BOILER TYPE MAKE SURE THAT THE FITTINGS FOR BOILERS TESTED IN THE PLUM LABORATORIES ARE COMPATIBLE WITH FITTINGS FOR SOLD BOILERS IT IS...

Страница 46: ......

Страница 47: ...47...

Страница 48: ...Ignatki 27a 16 001 Kleosin Poland tel 48 85 749 70 00 fax 48 85 749 70 14 plum plum pl www plum pl www plumelectronics eu...

Отзывы: