7093-601B • 2/5/18
(877) 447- 4768
24
Troubleshooting
Troubleshooting
Blockage Related
Fire starts but goes out
•
Confirm firebox is clean and clear (Zone 1)
- Ensure firepot holes are clear
•
Inspect stove body (Zone 2)
- Confirm exhaust probe is connected
- Inspect and clean the exhaust outlet
•
Confirm exhaust path is clean and clear (Zone 3)
Starts and stops frequently in automatic mode
• Determine if your room is experiencing varying temperatures due to repeated opening/
closing of doors or windows—correct if necessary
•
Examine stove body (Zone 2)
- Inspect ambient probe and confirm that at least 2” is exposed outside of stove
body
Slow or smoky start-up and/or lazy flame
•
Confirm exhaust path is clean and clear; clean your firepot and behind your baffles
inside your firebox (Zone 3)
•
Examine stove body (Zone 2)
- Align igniter so it is properly placed and centered
- Review fuel quality (see Pellet Fuel
information on page 5)
1
Zone
1
Zone
2
Zone
2
Zone
3
Zone
3
Zone