7093-601B • 2/5/18
29
Listing and Code
Approvals
Glass Specifications
This Stove is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please contact GHP Group Inc. for replacement
glass.
Electrical Rating (On High)
PHC Series: 115 VAC, 60 Hz, Start 2.6 Amps, Run 0.9 Amps
Listings and Certifications
Model
PHC90
Laboratory
OMNI-Test Laboratories, Inc.
Report No.
0061PS093E
EPA Certified
1.11 grams/hr
*BTU Input
11,055 - 47,378 / hr
*BTU Output
8,456 - 39,482 / hr
Efficiency HHV
82.3%
**Heating Capacity
Up to 2,200 sq. ft.
depending on climate zone
Vent Size
3” or 4” L or PL
Hopper Capacity
90 lbs (Approximate)
Fuel
Wood pellets
Shipping Weight
340 lbs
Standard
EPA Certification 2015, test method: ASTM
E2779-10
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
*BTU input/output will vary, depending on the brand of fuel you use in your stove.**Heating capacity depends on
climate zone, structure layout, insulation, windows, etc.
9-3/8 [238]
9-3/8 [238]
4 [102]
26-3/4 [679]
28 [711]
32-1/8
[816]
25-1/4 [642]
9-5/8
[246]
FLUE
15-3/4 [400]
Stove Dimensions
This manual describes the installation
and operation of the Brand Pleasnt
Hearth, Model PHC90 wood heater.
This heater meets the 2015 U.S.
Environmental Protection Agency’s
crib wood emission limits for wood
heaters sold after May 15, 2015.
Under specific test conditions this
heater has been shown to deliver heat
at rates ranging from 11,055 to 47,378
Btu/hr.
BTU & Efficiency Specifications