REQUIRED:
Use only 3” or 4” type “L” or “PL” pellet pipe.
CAUTION
•
Do not connect to any air distribution duct or system
•
Do not install a flue damper in the exhaust venting system of this stove
•
Do not connect this stove to a chimney flue serving another Stove
•
The structural integrity of the manufactured home floor, wall and ceiling/
roof must be maintained
C
C
Pro Tip
This unit can be installed with a 3 to 6 inch (76-152mm) Top Vent Offset Adapter Kit. The 3 to 6
inch (76-152mm) Top Vent Offset Adapter are tested to use 24 gauge single wall flue connector
or Listed double wall flue connector to Class A Listed metal chimneys, or masonry chimneys
meeting International Conference of Building Officials (ICBO) standards for solid fuel Stoves.
Getting Ready (Continued)
Pellet Venting
Adding bends in the exhaust path restricts air flow,
reduces performance and provides a collection point
for ash deposits requiring more frequent cleaning.