![pleasant hearth PH35PS Series Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/pleasant-hearth/ph35ps-series/ph35ps-series_owners-manual_1567637030.webp)
7077-801D • September 17, 2019
(877) 477- 4768
30
E. Alternate Masonry
D. Masonry
Non-combustible
Hearth Pad
Airtight Clean-out Door
Sheathing
2 in. (5.08mm) Minimum
Flashing
1 in. (25mm) Clearance
1 in. (25mm)
Clearance with Firestop
6 in.
(152mm)
Minimum
Fireclay Flue Liner
with Airspace
Concrete Cap
Tapete para Chimenea Incombustible
Puerta de
Limpieza
Hermética
Limpieza
Revestimiento
3 pulgadas (76
mm) como mínimo
1 pulgada (25 mm) de
espacio libre
Tapajuntas
Ducto de Arcilla
refractaria con
espacio libre
Tapa de
concreto
1 pulgada (25 mm)
de espacio libre con
Firestop
6 pulgadas
(152mm)
Mínimo
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with
this appliance. For assistance or additional information
consult a qualified installer, service agency or
your dealer.
WARNING
Fire Risk
Inspection of Chimney:
•
Masonry chimney must be in good condition.
•
Meets minimum standard of
NFPA 211
•
Factory-built chimney must be minimum 6
inch (152mm)
UL103 HT
.
WARNING