888-2408-002
5-21
WARNING: Disconnect primary power prior to servicing.
Maintenance and Alignment
STEP 7
All of the parameters in Table 5-1 are editable from the Diagnostics
Display and should be set to the values listed on the Factory test
Data sheet not necessarily the default values listed. If the Factory
Test Data is not available or you are not sure that the values in the
Factory Test Data are still valid then verify, and where necessary,
change the values to those listed in Table 5-1. (To edit any of these
screens, press and hold [D] and then press [C]. The edit controls
should appear on the screen).
STEP 8
Press the HIGH ON button and then quickly press and hold the
LOWER button for 10 seconds. This will turn the transmitter on at
zero power output.
STEP 9
Proceed to "5.14 System Configuration and Calibration" on page 5-
22.
Table 5-1 EEPROM U39 Parameter Checklist
Platinum Z5
Parameter
Default Settings
Forward Factor
0.007697 (see Figure 5-3)
Reflect Factor
0.000306 (see Figure 5-7)
IPA Factor
200
Exciter Factor
200
CAL Frequency
Set to your frequency
(Default = 98MHz)
Operating Frequency
Set to your frequency
(Default = 98MHz)
Cal APC Factor
07.58 (see Figure 5-4)
100% TPO Set
5.00kW
Max High Set
6.00kW
Max Low Set
2.50kW
UPS Setting
2.50kW
Low Power Alarm
4.50kW
VSWR Foldback
1.35
VSWR Fault
1.50
NOTE: Set to Factory Test Data numbers if available
Содержание Z5 CD
Страница 4: ...888 2408 002 WARNING Disconnect primary power prior to servicing...
Страница 6: ...888 2408 002 WARNING Disconnect primary power prior to servicing...
Страница 8: ...888 2408 002 WARNING Disconnect primary power prior to servicing...
Страница 10: ...888 2408 002 WARNING Disconnect primary power prior to servicing...
Страница 20: ...1 6 888 2408 002 WARNING Disconnect primary power prior to servicing Introduction Specifications...
Страница 192: ...6 40 888 2408 002 WARNING Disconnect primary power prior to servicing Troubleshooting...
Страница 193: ...888 2408 002 7 1 WARNING Disconnect primary power prior to servicing Parts List 7 1 Part List Index...
Страница 194: ...7 2 888 2408 002 WARNING Disconnect primary power prior to servicing Parts List...