4-42
888-2408-002
WARNING: Disconnect primary power prior to servicing.
Overall System Theory
4.7.4
PA Controller Boards
There are two (2) PA Controller Boards in the Z5 transmitter. They utilize micro-
controllers which report to the Master Controller, but operate independently of the
Master. Each controls half or 8 of the 16 PAs. Table 4-1 on page 4-60 shows which
PAs are controlled by each of the PA Controller Boards. The two boards are
identical except for the programmable ID number which is set with DIP switches on
the board to determine which board is PA Controller 1 and which is PA Controller 2.
The following is a listing of the PAs under the control of each PA Controller:
PA Controller #1 (PAC1)
•
A1, A2, A5, A6, B3, B4, B7, B8
PA Controller #2 (PAC2)
•
A3, A4, A7, A8, B1, B2, B5, B6
The PA Controllers are responsible for the following:
•
Turn on/Turn off of the PAs via the PA gate bias voltage.
•
Metering, status and fault monitoring of the PAs and the isolation resistors associ-
ated with them.
•
Control of the combiner isolation switches (located on the isolation boards)
which are associated with the PAs under its control.
•
Crossover protection (the ability to mute the PAs which are controlled by the
other PA Controller Board in case of a failure).
4.7.4.1 PA Turn On/Turn Off
The PA Controllers primary responsibility is to turn the PAs on and off. The PAs are
turned on and off by varying the bias voltage on the gates of the MOSFETs on the
PAs. If the gate voltage is -0.6V, the PA is turned on full. If the gate voltage is -18V,
then the PA is turned off. This means the PA Controllers have the ability to turn off
or MUTE each PA individually, or all at the same time if it is necessary to MUTE
the entire transmitter RF output.
Whenever a defective PA is to be shut off or MUTED, all of the PAs will be
MUTED for 120mS while the defective PA is disconnected from the combiner by
the isolation switch. The rest of the PAs are then turned back on.
4.7.4.1.1 Control Distribution and Controller Failure
Each PA Controller controls half (8) of the PAs, see Table 4-1 on page 4-60. Note
that each PA Controller Board controls two PAs on each foursome. This pattern of
control distribution allows for maximizing of power output if one of the PA
Controller Boards fails.
Содержание Z5 CD
Страница 4: ...888 2408 002 WARNING Disconnect primary power prior to servicing...
Страница 6: ...888 2408 002 WARNING Disconnect primary power prior to servicing...
Страница 8: ...888 2408 002 WARNING Disconnect primary power prior to servicing...
Страница 10: ...888 2408 002 WARNING Disconnect primary power prior to servicing...
Страница 20: ...1 6 888 2408 002 WARNING Disconnect primary power prior to servicing Introduction Specifications...
Страница 192: ...6 40 888 2408 002 WARNING Disconnect primary power prior to servicing Troubleshooting...
Страница 193: ...888 2408 002 7 1 WARNING Disconnect primary power prior to servicing Parts List 7 1 Part List Index...
Страница 194: ...7 2 888 2408 002 WARNING Disconnect primary power prior to servicing Parts List...