42
Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3
Technical data
9 Technical data
Input variables
7000 R3
9000 R3
11000 R3
14000 R3
16000 R3
Max. PV power
6,700 Wp
9,000 Wp
11,200 Wp
14,600 Wp
16,900 Wp
Max. DC power (cos
ϕ = 1)
6,100 W
8,200 W
10,200 W
13,300 W
15,350 W
PV voltage range, M P P T
350 – 720 V
350 – 720 V
Max. DC voltage
900 V
900 V
Max. input current
2 x 10 A
2 x 13 A
2 x 16 A
2 x 21 A
2 x 24 A
Number of string inputs
2 x 2
2 x 2
Number of MPP trackers
1
1
Short circuit current
14 A
18 A
22 A
29 A
33 A
Earth connection monitoring
Isolation check
Isolation check
Output variables
7000 R3
9000 R3
11000 R3
14000 R3
16000 R3
Rated AC power (cos
ϕ = 1)
6,000 W
8,000 W
10,000 W
13,000 W
15,000 W
Rated AC current intensity
8.7 A
11.6 A
14.5 A
18.9 A
22.0 A
Max. apparent power
6,000 VA
8,000 VA
10,000 VA
13,000 VA
15,000 VA
Max. AC current intensity
11.2 A
14.8 A
18.5 A
22.0 A
22.0 A
Max. short circuit current
117.4 A
117.4 A
Switch-on current
1.54 A
1.54 A
Feed-in operation begins from ...
20 W
20 W
Mains voltage working range
3AC 230 V / 400 V + N (+/– 20 %)
3AC 230 V / 400 V + N (+/– 20 %)
Feed-in / monitoring phases
3 feed-in phases / 3 monitoring phases
3 feed-in phases / 3 monitoring phases
Max. network impedance permitted (Z
max
)
–
–
–
402 m
W
345 m
W
Internal use over night
< 2 W
< 2 W
Mains frequency
50 Hz (+/– 5 %)
50 Hz (+/– 5 %)
Short-circuit strength
Yes
Yes
Power factor (cos
ϕ)
0.7 ind ... 0.7 cap
0.7 ind ... 0.7 cap
Earth connection monitoring
AFI
AFI
Efficiency
7000 R3
9000 R3
11000 R3
14000 R3
16000 R3
Max. efficiency
98.4 %
98.4 %
Euro efficiency
97.7 %
97.8 %
97.9 %
98.0 %
98.0 %
Type name