15
Installation and user guide PLATINUM Inverter 7000 R3, 9000 R3, 11000 R3, 14000 R3, 16000 R3
Installation
CAUTION
Damage to property!
f
Use only the original DC voltage Multi-Contact MC4 cable plug.
f
Ensure that the max. DC voltage permitted is not exceeded.
f
Ensure that the max. direct current permitted per string is not
exceeded.
▪
Ensure that the number and type of solar modules and the PV power
are the same in every string.
▪
Always connect an even number of strings:
–
String 1 (TA) and string 2 (TB)
– or –
–
String 1 and string 3 (TA), string 2 and string 4 (TB)
▪
The inputs TA and TB must be symmetrically wired.
–
+
–
+
1. Furnish the DC voltage cable for every
string with original Multi-Contact MC4
plugs. Make sure that the polarity is
correct here.
String 3
String 1
String 2
String 4
2. Remove protective caps from the
required DC connections.
3. Insert prepared DC voltage connectors
in the DC connections, ensuring that
the plugs lock in place correctly.
4. To ensure the type of protection,
place protective caps on unused plug
connectors.