background image

BLSL3060

BLSL3060 Manual_Layout 1  6/21/2015  10:44 AM  Page 1

Содержание BLSL3060

Страница 1: ...BLSL3060 BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 1 ...

Страница 2: ...aintenance Instructions Intended Use Types of Installations Mounting Instructions Entrapment Protection Inductive Loops Alarm Reset Switch Warning Placards Electrical Limit Switches Primary Secondary Connections Loop Rack Accessory Connections Selectable Features Solar Installation Parts Diagram Gate Operator Trouble Shooting Procedure 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 20 21 22 23 26 27 2...

Страница 3: ... PRUH VLQJOH family units hotel garages retail store or other building servicing the general public Industrial Limited Access Vehicular Gate Operator Class III A vehicular gate operator or system intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public Restricted Access Vehicular Gate Operator Class ...

Страница 4: ...vice is not required to cover both directions A combination of one Type B1 for one direction and one Type B2 for the other direction is the equivalent of one device for the purpose of complying with the requirements of either the primary or secondary entrapment protection areas a Entrapment protection Types Type A Inherent entrapment protection system Type B1 Provision for connection of supplied w...

Страница 5: ...re path of travel of the vehicular gate c The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment Swinging gates shall not open into public access areas d The gate must be properly installed and work freely in both directions prior to the installation of the gate opera tor Do no...

Страница 6: ...ure to adjust and retest the gate operator properly can increase the risk of injury or death 5 Use the emergency release only when the gate is not moving repairs to gate hardware 7 The entrance is for vehicles only Pedestrians must use separate entrance 8 SAVE THESE INSTRUCTIONS Maximum Gate Weight 3000 lbs Maximum Gate Length 60 feet Opening Time 12 per second Power Requirements 120 VAC Single Ph...

Страница 7: ...eature on the operator QVWDOODWLRQ DOO FRQQHFWLRQV SURJUDPPLQJ UHSDLU DQG PRGL FDWLRQV PXVW EH GRQH E D TXDOL HG SURIHVVLRQDO JDWH RSHUDWRU LQVWDOOHU QG XVHUV KRPH RZQHUV PXVW FDOO D TXDOL HG SURIHVVLRQDO JDWH RSHUDWRU LQVWDOOHU IRU SURJUDPPLQJ FKDQJHV UHSDLUV DQG PRGL FDWLRQV Although all Platinum Access Systems gate operators are virtually maintenance free to an end user home own minimal mainten...

Страница 8: ...7 Intended Use The operator is intended for installation on a vehicular slide gate only The operator IS NOT intended to be used for any pedestrian gate BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 9 ...

Страница 9: ...8 Types of Installations FRONT INSTALLATION Gate Operator Open Position Closed Position Gate Operator Concrete Pad Track Concrete Pad BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 10 ...

Страница 10: ... Chain As Shown etail of Rear Install ain Ro t e Gate Operator Concrete Pad Gate Operator Concrete Pad Gate Operator Open Position Closed Position Track Concrete Pad See Detail Below Parts Not Supplied by Platinum Access Systems BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 11 ...

Страница 11: ...flooding of the operator 3 To support the weight of the gate we recommend the path of the track should be at least 10 wide and 6 deep Drill for a 1 2 x 31 2 Red Head Anchor 4 Places 20 24 10 6 Track 2 91 4 Minimum 4 Minimum 28 203 8 4 Gate Operator Concrete Pad Gate Operator Concrete Pad Install a Positive Stop at Both Ends of the Track Operator Cover Track Concrete Pad Track Concrete Pad Gate Gra...

Страница 12: ...ons for proper installation Refer to pg 10 for hole center dimensions NOTE Pre installation procedure Manually open and close the gate ensuring there is sufficient space between adjacent walls and gate While pushing the gate to the open and closed positions confirm that the wheels turn freely on the track and there are no obstacles Ensure that there is plenty of space for the guide rollers and tha...

Страница 13: ...g the gate operator rollers prior to welding the chain brackets provided Correct Correct Incorrect Incorrect Manual Release When manual operation is required Open the front plug locate the Reset Switch and turn it to the OFF position Turn the switch to the RESET position to resume normal operation BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 14 ...

Страница 14: ... safety conditions encountered in your gate application We recommend the use of EMX IRB 325 photoeyes to comply with UL325 Gate in Closed Position Photo Beam Unit Reflector Contact Sensor Contact Sensor Potential Entrapment Area Note This type of installation DOES NOT reverse the gate all the way back to its limits when the sensors are obstructed This installation is only to protect against entrap...

Страница 15: ...that pass through it a center loop is recommended and should be installed A center loop prevents the gate from closing when a vehicle is between the safety loops Safety loops are required when using a center loop See Loop Wiring Outside Safety Loop Inside Safety Loop Exit Loop Twist wires outside of loop do NOT twist wires inside of loops Outside Inside X 5 X X X Gate in Closed Position Outside Sa...

Страница 16: ... the rebar Saw Cut Existing Surface Cut deep into the existing surface place a 45 cut at the corners to prevent sharp edges from damaging the loop wire Notch out for the T connection where the lead wire connects to the loop Remove all debris from the finished cut with compressed air Place the loop into the saw cut Place backer material into the saw cut over the loop wire and pack tightly Place a h...

Страница 17: ...entered An audio alarm is not required for Classes III and IV To reset the alarm the Stop command can be given in two different ways 1 The Built in Stop switch on the control board 2 The External Stop button in the line of sight of the gate away from moving parts of the gate and out of reach of children WARNING PLACARDS INSTALLATION WARNING To reduce the risk of severe injury or death to person pl...

Страница 18: ...und wire too short break it or destroy its integrity replace it with a single wire length Prevent unnecessary turns or loops in ground wires The gate operator and the battery charger require a single phase AC line to operate 1 Turn off the breaker for the circuit you are using 2 Select the proper voltage on the power board 3 Connect the incoming power wires to the proper terminals 4 Turn on the br...

Страница 19: ...rness to J14 and MOTOR CTL harness to J4 On the OPEN DIR switch Select RIGHT to open right Select LEFT to open left OPEN LEFT OPEN RIGHT White Green Black Red White Green Blue Black Blue Green White Red Red Black White Green BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 20 ...

Страница 20: ...s without interruption from limit to limit to execute a Learn Cycle Note Open and close the gate without interruption every time you change the adjustment Gate Opens to Right Left Limit Switch Open limit Right Limit Switch Close limit Gate Opens to Left Left Limit Switch Close limit Right Limit Switch Open limit Left Limit Switch Left Limit Switch Cam Set Right Cam In This Direction Set Left Cam I...

Страница 21: ...the first full open and close cycle the gate operator will run at low speed During subsequent cycles the gate operator will speed up at start and slow down prior to reaching its limits 3 Verify that the gate opens and closes to the desired position Note When slightly adjusting the open or close limit position s the operator will auto matically adapt the changes When relearning is needed push and h...

Страница 22: ...onized operation with a second gate operator Shielded Cable NOTE Use 18 Guage Wire for runs up to 100 Conduit Caution Do not run Primary Secondary communication cable in the same conduit as the power supply 120 220V cable Inside Outside Primary Primary Operator Secondary Interconnecting Conduit Opens First Blk Wht Green Red Silver BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 23 ...

Страница 23: ...ty Twist Wire Outside the Loop 6 Twists Foot Until Its Connection to the Loop Rack Inside Safety Loop Outside Safety Loop Exit Loop Loop Connector Control Board Connector Loop Rack GOC LDR Safety Exit Center 28V Gnd Gnd Gnd BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 24 ...

Страница 24: ...ontrolled power supply for Photo Beam The power will be turned off when gate is in close position to save battery Photo Beam TX Option for Solar Power Input ONLY To decrease the possibility of vehicle entrapment on the gate vehicle loop detectors need to be installed The edge sensor and the photo electric beam can be used for secondary entrapment protection on every installation to prevent pedestr...

Страница 25: ... By having the radio receiver connected as illustrated and with the Timer OFF Every command of the radio transmitter will control the gate as follow A First command opens the gate B Second command CLOSE the gate if at open position C Third command OPEN the gate D Any subsequent commands will continue in the same order to control the gate This type of configuration is not recom mended for a commerc...

Страница 26: ... switches for Open and Close must be normally open type The switch for Stop must be normally close type They all can be using the same common ground The control switch box should be within sight of the gate out of reach of children and away from moving parts of the gate If no guard station or STOP switch is installed a jumper must be inserted between STOP NC and GND pins OPEN STOP GND STOP OPEN CL...

Страница 27: ...ower source This will prevent damaging the battery in the event of line power failure Green Black White Red Supplied with Lock Kit 24VDC Magnetic Lock PA MAG13 Supplied with Lock Kit Locks OPTIONAL ACCESSORY part PA MAG13 ACCESSORY CONNECTIONS continued BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 28 ...

Страница 28: ... function disabled is the close command ADVANCING LOCK SELECT PRIMARY SECONDARY OPERATOR SELECT I Auto Open To enable the Auto Open feature Select the DIP switch to AUTO OP position ADV MLOK To set the maglock to be engaged before the gate reaches the close or open position Select the DIP switch to ADV MLOK position Primary Secondary To set the operator to Secondary Select the DIP switch to SECOND...

Страница 29: ...y operator Instant Reversing Sensor The Obstruction Sensor needs to be adjusted to compensate for the installation and gate weight The overload adjustment is provided to set the gate sensitivity a If the gate reverses by itself or stops in midcycle it is too sensitive b If the gate hits an object and does not reverse or stop it is not sensitive enough c Clockwise increases sensitivity counter cloc...

Страница 30: ... controller installation please call Technical Support FAIL SAFE SECURE Fail Safe Secure On Fail Safe Off Fail Secure Fail Safety Input ON ON ON ON OFF OFF OFF OFF Battery Detection Normal Normal Low OFF Low OFF Normal Normal Low OFF Low AC Detection Normal OFF Normal OFF Normal OFF Normal OFF Output Secure Fail Safe Fail Safe Fail Safe Secure Fail Secure Fail Secure Fail Secure Note When the outp...

Страница 31: ...h Gear Box 7 Loop Rack 8 Limit Switch Bracket 9 Limit Switch Holder 10 41B25 Sprocket 11 Idler Pulley 2 12 Breaker Switch 13 Control Board 14 Toroid Transformer 15 Battery 24V 33 ampHr 12V DC x 2 16 120V Receptacle 17 Alarm 18 Limit Switch Harness 19 Power Harness 20 Operator Cover 21 Warning Placard 22 Battery Holder 2 23 EMI Board 24 Control Box Bracket 2 25 Worm Gear BLSL3060 Manual_Layout 1 6 ...

Страница 32: ...on is correct Connect from the receiver common pin to operator main board 28Vpin and connect the receiver 24V pin to operator main board GND pin If your connection is wrong it can freeze the operator Next turn the AC switch and battery breaker switch OFF Wait for 30 seconds Then turn these two switches back ON Then reset the operator c Power Failure Check battery connection and check each battery ...

Страница 33: ...ator If any input device is connected to the Secondary unit please change it to connect to the primary unit Then press Reset to rest the operators e Gates Hit Each Other Master Slave Slide Gates One gate over traveled Make sure the limit nut has set correctly Please make sure the end user never use pad lock to lock the gates together Only maglock can be used to lock the gates Please correct this p...

Страница 34: ...PLATINUM ACCESS SYSTEMS 2013 Platinum Access Systems Inc All Rights Reserved BLSL3060 Manual_Layout 1 6 21 2015 10 44 AM Page 36 ...