BARRIER 

33

Routine Maintenance 

Perform the following operations and checks every 6 months according to intensity of use of the automa-

tion. Disconnect the power supply connection and batteries (if present):

• 

Clean and oil the levers and check nuts and screws are well tightened.

• 

Clean and grease the joint and the spring-post as shown in the figure.

• 

Check the electrical connections.

• 

Check that the manual release is operating correctly.

• 

Check that the rod is balanced correctly. 

Check the value of the capacity of the motor condenser.

 

Reconnect the power supply connection and batteries (if present):

• 

Check that the limit switches are working correctly:

• 

Check that obstacle detection is operation correctly.

• 

Check that all control and safety functions are working correctly.

OBSTRUCTION/INSTANT REVERSING SENSOR

Содержание BARRIER

Страница 1: ...PLATINUM ACCESS SYSTEMS INSTALLATION INSTRUCTION MANUAL BARRIERS Vehicular gate operator ...

Страница 2: ...the Opening and Closing Position 14 6 Electrical Installation Electrical Power Source Connection to circuit board 15 Battery and Power Supply Connections Diagram 16 7 Inductive Loop Installation 17 8 Loop Rack Installation 18 9 Accessory Connections Electrical Circuit Board Pictorial Layout 19 Open Commands 20 Detection Loop 21 Radio Receiver 22 Light and Flash control 23 Primary Secondary 24 Guar...

Страница 3: ... account applicable laws and directives Good Working Methods installation premises system operating logic and the forces developed by the motorized barrier The safety devices must protect any areas where the risk exists of being crushed cut or gragged or where there are any other risks generated by the motorized barrier Apply hazard area notices required by applicable regulations Each installation...

Страница 4: ...th 600 cycles per day Applications VERY INTENSE for condominium industrial and commercial entrances parking spaces with very intense vehicle or pedestrian access Performance characteristics are to be understood as referring to the recommended weight approx 2 3 of the maximum permissible weight When use with the maximum permissible weight a reduction in the above mentioned performance can be expect...

Страница 5: ... SPRD51 1 1 REF CODE Description 1 24 V motor with encoder 2 Main Control Board GOC 6000 3 Mechanical stop adjusting 4 Key Release 5 SPGY SPGN SPRD38 SPRD51 Grey spring Green spring Red spring ø 1 5 Red spring ø 2 6 Control Panel Box 7 Limit switch 8 Limit switch sliding block 2 21 ...

Страница 6: ...revious ones The technical data shown in this Price List are not binding For further information see the relevant brochures and technical manuals which can also be viewed in our web site www ditecentrematic com I dati tecnici riportati sul presente Listino Prezzi non sono vincolanti Per ulteriori informazioni consultare i relativi depliant e manuali tecnici visionabili anche sul sito www ditecentr...

Страница 7: ...Door 11 BBEN Barrier Enclosure 12 BAHBA Arm Holder Bracket Assy 13 AR Release Arm with Lock 14 ARB Release Device Bezel 15 ENTOPC Enclosing Top Cover 16 AHBRC Arm Holder Bracket Cover 17 AHBRCL Arm Holder Bracket Cover Lid 18 AHBRCR Arm Holder Bracket Cover Ring 19 RPIN Release Pin 20 Gmotor Gearmotor Assy 21 Batteries ...

Страница 8: ...etector device for traffic monitoring A Connect the power supply to an approved omnipolar switch with an opening dis tance of the contacts of at least 0 1 not supplied The connection to the mains must be made via an independent channel separated from the connections to command and safety devices Note The given operating and performance features can only be guaranteed with the use Platinum accessor...

Страница 9: ...Technical Support 909 259 6001 BARRIER 8 Mounting Installation PRODUCT DIMENSIONS ...

Страница 10: ... Concrete Area 24 2 Conduit Pipe Come out from the center point of the concrete base 4x 5 x3 5 anchors Prepare a 24 x17 5 rectangle area and dig 17 deep into the ground Then pour the concrete mixer into the hole and make sure this concrete block is at least 6 above the ground do not forget to place the conduit pipe first before the concrete mixer ...

Страница 11: ...Technical Support 909 259 6001 BARRIER 10 ARM ASSEMBLY Arm Installation Cut the length of the bar to L PL 10 82 Install the bar as shown in the figure L only PL 15 8 11 1 3 2 4 5 ...

Страница 12: ... 50 SPGN 11 50 14 80 SPRD38 14 80 17 SPRD38 17 19 SPRD51 PL Feet 6 0 6 5 SPGY 6 5 8 2 SPGN 8 2 9 5 SPGN 9 5 10 5 10 5 13 4 SPRD38 SPGN 13 4 15 7 SPRD38 15 7 19 SPRD51 Determine arm length From table select the proper strut From the picture select the proper position on the gear arm to mount the strut 1 2 3 Arm Installation ...

Страница 13: ...Technical Support 909 259 6001 BARRIER 12 PICTORIALS FOR REFERENCE Arm Installation 62 7 FP A B C A SPGY 27 5 SPGN 27 5 SPRD 28 5 SPRD51 28 5 Spacer Right Opening Left Opening Locked Nut B Locked Nut D ...

Страница 14: ...d compound glue laced nut see page 12 1 2 3 4 5 Using the nut D above the spring on the strut compress the spring until the arm is balanced at an angle between 5 to 30 above the floor when in this position the arm will be stationary and angles upwards see page 12 Warning Using the table from page 12 as reference determined the measurement A for the strut that is being used make sure that measureme...

Страница 15: ... position of the bar using the special screws A Adjust the opening and closing limit switches using the cams C so that the switches are activated approx 0 1 before the mechanical stop B A A B C C Arm Installation LIMIT SWITCH ADJUSTMENTS FOR THE OPENING AND CLOSING POSITION ...

Страница 16: ... ground rod for your lo area The ground wire must be a single whole piece wire Never splice two wires for the ground wire If cut the ground wire too short break it or dest its integrity replace it with a single wire leng Prevent unnecessary turns or loops in ground wir The gate operator and the battery charger require a single phase AC line to operate 1 Turn off the breaker for the circuit you are...

Страница 17: ...al Installation 24V Batteries Power Harness Plug Outlet Receptacle Earth Ground Green Yellow Neutral White Hot Black Green Reset Switch Solar Regulator Out White White Red Red Red Black Green Black Red White BATTERY AND POWER SUPPLY CONNECTION DIAGRAM ...

Страница 18: ...the gate away from moving parts of the gate and out of reach of children STOP 5 Minimum Manual Stop Button 6 COM N C STOP WARNING PLACARDS INSTALLATION WARNING To reduce the risk of severe injury or death to person please follow these instructions All Warning Sings and Placards must be mounted where visible in the area of the gate A minimum of two 2 Warning Placards shall be mounted One on each si...

Страница 19: ... Inside Outside Center Exit Center Gnd Safety Twist Wire Outside the Loop 6 Twists Foot Until Its Connection to the Loop Rack Inside Safety Loop Center Loop Outside Safety Loop Exit Loop Loop Connector Control Board Connector Loop Rack GOC LDR Safety Exit Center 28V Gnd Gnd Gnd ...

Страница 20: ... Light and Flash Control Flash Enable Jumper On Board Control Close Timer Setting Sense and Open Angle Adjust Power Supply Guard Station Front Cover Lock Motor Encoder Input Open Close Speed Adjust Primary Second Barrier Link Motor and Limit Switch Optional Photo Eye Input ELECTRICAL CIRCUIT BOARD PICTORIAL LAYOUT ...

Страница 21: ...EQ STK J2 CMD FIRE Keypad Fire Box COMMANDS 1 FIRE Open barrier whenever fire emergency happens 2 STK Strike open 3 SEQ Sequential open input used in barrier main Slide Swing gate gate configuration to sequentially open the barrier and main Slide Swing gate OPEN COMMANDS ...

Страница 22: ... SAFETY LOOP DETECTOR SAFE EXIT To decrease the possibility of vehicle entrapment on the gate Vehicle loop detectors need to be installed The edge sensor and the photo electric beam can be used for secondary entrapment protection on every installation to prevent pedestrian or animal entrapment These accessories must be UL 325 compliant devices ...

Страница 23: ...an control the gate Open Close By having the radio receiver connected as illustrated and with the Timer OFF Every command of the radio transmitter will control the gate as follow A First command opens the gate B Second command CLOSE the gate if at open position C Third command OPEN the gate D Any subsequent commands will continue in the same order to control the gate This type of configuration is ...

Страница 24: ... COM FL_NO J9 LIGHT 1 FL_NO COM FL_NC This provides NO NC relay connections for controlling flash lights The flash is active when the barrier is operating enable jumper is plugged 2 L_NO COM L_NC This provides NO NC relay connections for turn on light when barrier is operating or flash when timer is running ...

Страница 25: ... Connections PS_A PS_B GND SEC PRIMARY UNIT PS_A PS_B GND SEC SECONDARY UNIT SECONDARY UNIT You can setup the Primary Secondary connection as shown below Primary PS_A Primary PS_B Primary GND Secondary PS_A Secondary PS_B Secondary GND PRIMARY SECONDARY ...

Страница 26: ...es for Open and Close must be normally open type The switch for Stop must be normally close type They all can be using the same common ground The control switch box should be within sight of the gate out of reach of children and away from moving parts of the gate If no guard station or STOP switch is installed a jumper must be inserted between STOP NC and GND pins GUARD STATION ...

Страница 27: ...Technical Support 909 259 6001 BARRIER 26 Accessory Connections Power brown NO Power Blue Comm OPTIONAL SOLAR POWER DIAGRAM ...

Страница 28: ...Technical Support 909 259 6001 BARRIER 27 Accessory Connections Short JP4 pin to make the LED light flash OPTIONAL FLASH ENABLE JUMPER N RIGHT 2 4 V BAT N LEFT JP4 FLEN ...

Страница 29: ...UNCTIONALITY 1 on off red light to indicate on the electrical circuit board whether the barrier arm is lock or not 2 In addition is associated with the Front Cover Lock component and its functionality FUNCTIONALITY 1 built in internal alarm that automatically sounds off when something is wrong ALARM ALARM ULOK 9V 2A POWER SUPPLY ...

Страница 30: ...Technical Support 909 259 6001 BARRIER 29 Manual Operation of the Barrier Gate Using Open Stop Close onboard button to Open Stop or Close the arm respectively OPEN STOP CLOSE COMMAND ON CIRCUIT BOARD ...

Страница 31: ...emove the key WARNING do not release with the springs under tension without rod Perform rod locking and release with the motor switched off Do not enter the operating range of the rod When the barier is released the rod may move of its own accord When the hatch is closed but the key is still horizontal the release micro switch is open and all the operations are stopped To deactivate the barrier th...

Страница 32: ...Technical Support 909 259 6001 BARRIER 31 ARM SPEED Manual Adjustments Used to Adjust Barrier Up and Down Speeds ...

Страница 33: ...ad adjustment is provided to set the gate sensitivity a If the gate reverses by itself or stops in midcycle it is too sensitive b If the gate hits an object and does not reverse or stop it is not sensitive enough c Clockwise increases sensitivity counterclockwise decreases sensitivity Test and adjust for proper reversing pressure OBSTRUCTION INSTANT REVERSING SENSOR ...

Страница 34: ...tightened Clean and grease the joint and the spring post as shown in the figure Check the electrical connections Check that the manual release is operating correctly Check that the rod is balanced correctly Check the value of the capacity of the motor condenser Reconnect the power supply connection and batteries if present Check that the limit switches are working correctly Check that obstacle det...

Страница 35: ...y works with Platinum Access Slide or Swing Gate Operators 1 The Barrier Arm receives an open command from your access control 2 The Barrier Arm remains closed and sends an open signal to the synchronized operator 3 The Barrier Arm will open once the synchronized operator reaches its open limit Swing Slide Gate Open Limit Switch GND GND GND STK STK SEQ FIRE COM NO NC FIRE Swing Slide Gate Operator...

Страница 36: ...chnical Support 909 259 6001 PLATINUM ACCESS SYSTEMS 1725 E Grevillea Court Ontario CA 91761 Phone 909 259 6000 I Fax 909 923 7890 www PlatinumASI com 2015 Platinum Access Systems Inc All Rights Reserved ...

Отзывы: