EN001 H01
59
12.6.16 BT only***
Attention!
If this option is activated, the electrofusion control unit can only be controlled by the app via
Bluetooth.
To deactivate this option after a restart, you must have permission to access the system
configuration.
Step
Action
1
Accessing the "BT only" option
1.1
Select the entry "Compensation" in the system configuration, using the ▲
-
and ▼
-buttons.
2
Changing the "BT only" option
2.1
The ◄ ► buttons are used to move the marking (*) from the "activated" (+) column to the
„deactivated“ (-) column and vice versa.
2.2
After having this option changed in the system configuration press the green start button to accept
the change and acknowledge the following safety prompt "Are you sure?"by again pressing the
green start button.
You can abort the input by pressing the red stop button.
***) Only with electrofusion control units that have Bluetooth functionality.
13. Troubleshooting and maintenance
13.1 Replacement of the welding terminals
The welding terminals should be checked on a regular basis and, if necessary, replaced as soon as they are
damaged or lose contact force (see chapter
8 "Spare parts and accessories").
Step
Action
1
Switch off the electrofusion control unit and disconnect it from the mains supply or
generator!
2
Pull off the red resp. black PVC cap.
3
Hold the front part of the brass contact with a pipe wrench and screw the welding terminal
with a 8 mm wrench out of the brass contact.
4
If your electrofusion control unit is SmartFuse-capable, then note that, when changing the
welding terminals, the red terminal contains a probe tip! Only use spare parts and welding
terminals provided by PFS.
5
Screw a new terminal plug into the brass piece. Check for firm fit.
6
Shove the PVC cap back over the welding terminal. Approximately 15 mm of the terminal
must stand out of the PVC cap.