TEST MODE
Each LF 6600 automatically enters the Test mode each time it is powered on. Power-on selftest
diagnostics are run to verify the operational readiness of the drive.
After the LF 6600 successfully passes the power-on selftests, the drive enters the Operating mode. When
the LF 6600 is in the Operating mode, the operator may manually enter the Test mode and invoke the
system function diagnostics.
The level of selftest diagnostic coverage is configurable via the "Test Thru:" option in the Diagnostics
menu. Lower level tests (numbers 0 through 6) verify basic drive hardware operation.
When errors are detected, the appropriate diagnostic message will be displayed on the DOC. Diagnostic
messages are presented to the operator in the form of failed test codes and Field Replaceable Unit (FRU)
mnemonics that can be relayed to a CE for repairing the malfunction.
If no problems are detected by the system function diagnostics, the display will show "Diagnostics
Complete. Press TEST to restart drive...".
Pressing TEST resets "Test Thru:" value to 00 and initiates selftest option. At the successful completion of
this selftest, the LF 6600 is returned to the operating mode, ready for normal operation.
Содержание LF 6602
Страница 1: ...THE PLASMON INFINITY LF 6602 OPTICAL DISK DRIVE User Manual P N 97654438 E...
Страница 6: ......
Страница 10: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 10...
Страница 20: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 20...
Страница 32: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 32...
Страница 42: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 42...
Страница 88: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 88...
Страница 92: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 92...
Страница 103: ......